5.11 Internal Temperature
5.11.1 Description
The sensor is equipped with internal temperature
monitoring. This records the device temperature as well as
the maximum and minimum values during production and
since the last time the sensor was restarted.
An upper and a lower threshold value can be defined for
the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or
undercut, the senor triggers IO-Link events.
5.11.2 Process Data
Object ID
Name
Description
Direction
0x0050 (80)
Device Temperature
Current device temperature in °C.
Output
Tab. 5-52: Internal temperature – Process data
5.11.3 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Device
Temperature
0x0052 (82)
0
R
10 bytes
INT16[]
Yes
–
Device
Temperature
1
R
2 bytes
INT16
No
–
Minimum
Device
Temperature
Since Reset
2
R
2 bytes
INT16
No
–
Maximum
Device
Temperature
Since Reset
3
R
2 bytes
INT16
No
–
Lifetime
Minimum
Device
Temperature
4
R
2 bytes
INT16
No
–
Lifetime
Maximum
Device
Temperature
5
R
2 bytes
INT16
No
–
Device
Temperature
Alarm
Configuration
0x0053 (83)
0
R/W
4 bytes
INT16[]
Yes
–
Lower Alarm
Level Device
Temperature
1
R/W
2 bytes
INT16
No
0x0055 (85)
Upper Alarm
Level Device
Temperature
2
R/W
2 bytes
INT16
No
0xFFF6 (−10)
Tab. 5-53: Internal temperature – ISDU (overview)
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LH10-S4
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Page 100: ...www balluff com...
Page 195: ......