www.balluff.com
63
english
5
Secondary Device Functions (continued)
5.9
Voltage and Current Monitoring
5.9.1 Description
The voltage and current module sends messages about
over-current, short-circuit, wire breakage, over-voltage and
under-voltage. Over-voltage and under-voltage detection
starts a timer. If the voltage level does not return to the
normal operating voltage threshold before the timer
expires, the module sends the messages.
The messages include device status, IO-Link events,
process data and LED signaling.
5.9.2 Mathematics/Algorithm
In SIO-operation, the threshold for under-voltage is 10 V
and is 30 V for over-voltage.
If the device is in IO-Link operation, the under-voltage state
occurs at 18 V and at 30 V for over-voltage.
5.9.3 Process Data
Object ID
Name
Description
Direction
0x0016 (22)
Overload / short-circuit
pin 2
TRUE = overload or short-circuit detected at pin 2.
Input
0x0017 (23)
Undervoltage
TRUE = the voltage level is below the threshold value.
Input
0x0018 (24)
Overvoltage
TRUE = the voltage level is above the threshold value.
Input
0x001A (26)
Cable break pin 2
TRUE = cable break detected at pin 2.
Input
0x0044 (68)
Overload pin 2
TRUE = overload detected at pin 2.
Input
Tab. 5-43: Voltage and current monitoring – Process data
Also see section
5.9.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Voltage
Monitoring
Detection
Time
Duration
0x2200
(8704)
0
R/W
2 bytes
UINT16
Yes
10
Tab. 5-44: Voltage and current monitoring – ISDU
Voltage Monitoring Detection Time Duration
This parameter is used to define how long the under-
voltage or over-voltage must be present before it is
displayed. The unit is given in milliseconds. The values
must be in the range between 10 and 1000, in increments
of 5 milliseconds. The default value is 10 milliseconds.
BOS R254K-UUI-LH10-S4
Photoelectric Sensors
Summary of Contents for BOS R254K-UUI-LH10-S4
Page 1: ...deutsch IO Link Konfiguration english IO Link Configuration BOS R254K UUI LH10 S4...
Page 2: ...www balluff com...
Page 3: ...BOS R254K UUI LH10 S4 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 99: ...BOS R254K UUI LH10 S4 IO Link Configuration english...
Page 100: ...www balluff com...
Page 195: ......