background image

 

 

 

 

BOL 27K-PS/NS-01

 

Line sensor

 

INSTRUCTION MANUAL

 

 
 
 
 
 
 

CONTROLS 

OUTPUT LED 

The yellow LED ON indicates that the NO output is closed. 

DISPLAY (green-coloured display) 

The display indicates the value of the measurement detected [operating mode function]. 
Please refer to the following paragraphs for the correct indications to follow during the acquisition or 
setting phase. 

M1, M2 LEDs  

The LED couple visualises the operating mode according to the table given below: 
 

OPERATING MODE 

M1 LED  

M2 LED 

Object beg. 

– Object end 

OFF 

OFF 

Object centre position 

OFF 

ON 

Width measurement 

ON 

OFF 

Area 

ON 

ON 

 
 

ALARM LED  

The blinking of the alarm LED indicates that the received signal is insufficient for the correct sensor 
functioning. In this case the “digital alarm” output is activated. 

SET PUSH-BUTTON 

Pressing the push-button for at least 2 seconds activates the self-setting procedure (2 thresholds => 
2 phases). 
A  long  pressure  on  the  button  (at  least  6  seconds)  allows  the  user  to  access  into  the  sensor 
parameter setting menu. 
Please  refer  to  the  following  paragraphs  for  the  correct  indications  to  follow  during  the  parameter 
setting phase. 
 

+/- PUSH-BUTTONS 

Pressing  the  +  or 

–  push-buttons  for  at  least  2  seconds allows the user to access into the manual 

adjustment mode of the 2 switching thresholds. 
The  contemporary  pressure  on  the  +  and 

–  push-buttons  (at  least  2  seconds)  activates  the 

acquisition procedure of the working area map. 
The  contemporary  pressure  on  the  +  and 

–  push-buttons (at least 6 seconds) activates  the setting 

procedure of the reflecting tape characteristics. 
Please refer to the following paragraphs for the correct indications to follow during functioning. 

INSTALLATION 

The sensor can be mounted by means of the three housing’s holes 
using two screws (M4x35 or longer) with washers. 
Various  orientable  fixing  brackets  to  ease  the  sensor  positioning 
are  available  (please  refer  to  the  accessories  listed  in  the 
catalogue). 
The operating distance is measured from the front surface of the 
sensor optics. 
The  M12  connector  can  be  oriented  at  three  different  positions 
using the specific fastening spring and rotating the block of 180°. 
 
 

DIMENSIONS 

mm

OUTPUT LED

42

42

50

18x

45°

2

50

14

11

5.5

25

31.

65

16

M12

15

20

17.05

7.75

DISPLAY

M1 LED

SET PUSHBUTTON

+/- PUSHBUTTON

-

+

SET

ALARM LED

M2 LED

A 1 2

OUT

 

 

TECHNICAL DATA 

Power supply: 

10 … 30 Vdc limit values 

Ripple: 

2 Vpp max. 

Consumption (output current excluded): 

70 mA max. 

Outputs: 

1 PNP or NPN output 

30 Vdc max.

 

(short circuit protection) 

1 PNP or NPN alarm output 

30 Vdc max.

 

(short circuit protection) 

4-20mA analogue output 

 

 

SYNC input: 

PNP (+V) 

Output current: 

100 mA max. 

Output saturation voltage: 

 2 V 

Switching frequency: 

> 130 Hz 

Indicators: 

4 digit display (GREEN), OUTPUT LED (YELLOW) 

1 ALARM LED (GREEN) 

2 LEDs (M1, M2) operating mode (GREEN) 

Setting: 

+, -, SET push-buttons 

Data retention: 

non volatile EEPROM memory 

Operating temperature: 

-

10 … 55 °C 

Storage temperature: 

-

20 … 70 °C 

Electrical protection: 

Class 2 

Operating distance (typical values): 

200 mm 

Measurement range: 

150 mm 

Minimum object detectable: 

0.9 mm 

Resolution: 

0.15 mm 

Linearity: 

1% max. 

Emission type: 

infared (875nm) 

Ambient light rejection: 

according to EN 60947-5-2 

Vibrations

:

 

0.5 mm amplitude, 10 … 55 Hz frequency, for each 

axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for each axis (EN60068-2-27) 

Housing  material: 

ABS 

Lens material: 

Glass window and lenses 

Mechanical protection: 

IP67 

Connections: 

8-pole M12 connector 

Weight: 

100 g. max. 

 

CONNECTION 

M12 CONNECTOR 

 

 

*

 Available only for the versions with RS485 serial interface (consult factory). 

NOTE: The wire colours are referred to the cables manufactured according to the European 
standard. 

FUNCTIONING 

The BOL 27K-PS/NS-01 sensor is a line sensor. 
The typical functioning diagram is shown in the drawing given below. The object to detect is placed in 
front  of  the  sensor  and  the  reflecting  tape  (inside  the  package)  behind  the  sensor.  The  sensor 
illuminated with IR lights the tape and receives the reflected light on a photodiode array. Each object 
placed between the reflecting tape and the sensor is naturally detected as a dark spot on a luminous 
background. 
The sensor has 5 operating modes: 

 

Object beg.

: the position of the first object edge is detected 

 

Object end

: the position of the second object edge is detected 

 

Object centre

: the centre of the object is measured 

 

Width

: the distance between the first and last object edge is measured  

 

Area

: the sum of all the object obscured zones is measured 

The following diagram shows the sensor output according to the possible object position inside the 
meaurement zone. 

 

 

First ob. edge 

Last ob. edge 

Center 

Width 

Area 

Beg 

End 

(Beg+End)/2 

End-Beg 

End-Beg 

End 

End 

End 

Beg 

Beg 

1023-Beg 

1023 

 

APPLICATION NOTES 

The  drawing  shows  how  the  same  object  can  generate 
different  obscured  zones  if  placed  in  different  positions 
inside  the  sensor  working  zone.  The  same  happens  if 
the object is placed at different distances. 
The “Area” operating mode is particularly sensitve to the 
reflecting  tape’s  characteristics  and  for  this  reason  the 
sensor  can  detect  the  main  specifications  of  the  tape 
used (please refer to “Advanced functions” paragraph”). 

 

Reviews: