background image

Balluff Network Interface /

 

EtherNet/IP

 BNI EIP-950-000-Z009

 

 

www.balluff.com 

 

2

 

Safety 

2.1

 

Intended use

 

  The BNI EIP-950-000-Z009 serves as an unmanaged switch module for connecting to an 

EtherNet/IP™ network. 

 

2.2

 

Installation and 
startup 

 

 

 

Note 

Installation and startup are to be performed only by trained specialists. Qualified 
personnel are persons who are familiar with the installation and operation of the 
product, and who fulfills the qualifications required for this activity. Any damage 
resulting from unauthorized manipulation or improper use voids the anufacturer's 
guarantee and warranty. The Operator is responsible for ensuring that 
applicable of safety and accident prevention regulations are complied with. 

 

 

2.3

 

General safety 
notes

 

 

Commissioning and inspection 

Before commissioning, carefully read the operating manual. 
The system must not be used in applications in which the safety of persons is dependent on 
the function of the device. 

Authorized Personnel 

Installation and commissioning may only be performed by trained specialist personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this operating 

manual 

Obligations of the Operating Company 

The device is a piece of equipment from EMC Class A. Such equipment may generate RF 
noise. The operator must take appropriate precautionary measures. The device may only be 
used with an approved power supply. Only approved cables may be used. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Intended use is ensured only when the housing is fully installed. 

 

Hazardous 
voltage

 

 

 

Note 

Disconnect all power before servicing equipment. 

 

 
 

 

 

Note 

In the interest of product improvement, the Balluff GmbH reserves the right to 
change the specifications of the product and the contents of this manual at any 
time without notice. 

 

 
 
 

Summary of Contents for BNI EIP-950-000-Z009

Page 1: ...BNI EIP 950 000 Z009 IP67 Module Unmanaged Switch User s Guide ...

Page 2: ...2 2 Installation and startup 3 2 3 General safety notes 3 Hazardous voltage 3 3 Getting started 3 1 Connection overview 4 3 2 Mechanical connection 5 3 3 Electrical connection 5 3 4 Ethernet connection 5 4 Technical data 4 1 Dimensions 6 4 2 Mechanical data 6 4 3 Operating conditions 6 4 4 Electrical data 6 4 5 Ethernet port 7 4 6 LED indicators 7 Appendix Product ordering code 8 Order information...

Page 3: ...The main steps for installing the device Section 4 Technical data for the device 1 3 Typographical conventions The following typographical conventions are used in this guide Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate where further information on t...

Page 4: ...on the function of the device Authorized Personnel Installation and commissioning may only be performed by trained specialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device...

Page 5: ... 3 1 Connection overview 1 Mounting hole 2 Ethernet Port 5 3 Status LED transmission rate 4 Ethernet Port 6 5 Status LED Link active 6 Ethernet Port 7 7 Ethernet Port 8 8 Ethernet Port 4 9 Ethernet Port 3 10 Ethernet Port 2 11 Ethernet Port 1 12 Label 13 Power supply 14 Ethernet Uplink Port 1 1 2 7 3 4 5 6 8 11 10 12 13 9 14 ...

Page 6: ...i 4 pin plug PIN Signal Demand 1 24 V Power 1 2 24 V Power 2 3 0 V Power 2 Common GND 4 0 V Power 1 Common GND 24 V DC Total current 9A The total current of all modules may not exceed 9A even when daisy chaining the actuator supply Function earth Figure 3 2 FE connection Note The FE connection from the housing to the machine must be low impedance and kept as short as possible 3 4 Ethernet connecti...

Page 7: ...y voltage 7 8 4 pin male Dimensions W x H x D in mm 68 x 224 x 32 4 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 580gr 4 3 Operating conditions Operating temperature Ta Storage temperature 5 C 55 C 25 C 75 C EMC Immunity Emission EMC directive 2004 108 EEC EN 61000 6 2 EN 61000 6 4 Shock vibration EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 EN 60068 2 64 4 4 Electrical da...

Page 8: ...low control Half Duplex Full Duplex IEEE 802 33x Pause 4 6 LED indicators LED indicators Ethernet IP module LED Indicator Function LED 1 Green Red Power Status LED 4 Red Off Module Status LED 7 Yellow Off Data transfer Uplink port active inactive LED 9 Yellow Off Data trans rate Uplink port 100Mbit s 50 Mbit s LED indicators ports Each M12 port is assigned LEDs which indicate the configuration or ...

Page 9: ...switch Variant 000 Standard version Mechanical version Z009 Material Die cast zinc housing Uplink 1 x M12x1 internal thread Power 7 8 external thread Ethernet ports 8 x M12x1 internal thread Order information Product ordering code Order code BNI EIP 950 000 Z009 BNI000F Scope of delivery The BNI EIP consists of the following components IO block 4 blind plugs M12 Ground strap Screw M4x6 20 labels U...

Page 10: ...Balluff Network Interface EtherNet IP BNI EIP 950 000 Z009 www balluff com 9 Notes ...

Page 11: ...Balluff Network Interface EtherNet IP BNI EIP 950 000 Z009 www balluff com 10 Notes ...

Page 12: ...P BNI EIP 950 000 Z009 www balluff com 11 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de www balluff com Nr 910590 E Edition 1312 Subject to modification ...

Reviews: