BNI EIP-104-105-Z015 

BNI EIP-202-105-Z015 

BNI EIP-302-105-Z015 

EtherNet/IP IP67 Modules  

User’s Guide 

 

Summary of Contents for BNI EIP-104-105-Z015

Page 1: ...BNI EIP 104 105 Z015 BNI EIP 202 105 Z015 BNI EIP 302 105 Z015 EtherNet IP IP67 Modules User s Guide ...

Page 2: ...ort 7 4 Technical data 8 4 1 Dimensions 8 4 2 Mechanical data 8 4 3 Operating conditions 8 4 4 Electrical data 8 4 5 Ethernet 9 4 6 Function indicators 9 Module status 9 Port 9 5 Process Data 10 5 1 Data Configuration 10 BNI EIP 302 105 Z015 10 5 2 Process Data Inputs 10 BNI EIP 302 105 Z015 10 5 3 Process Data Output 10 BNI EIP 302 105 Z015 10 5 4 Data Configuration 11 BNI EIP 202 105 Z015 11 5 5...

Page 3: ...Display information 13 6 5 Design and Symbols 14 6 6 Startup 14 6 7 Main Menue 14 6 8 IP Setup 15 6 9 IP Config 15 6 10 Module information 16 6 11 General Informations 16 7 Webserver 17 7 1 General 17 7 2 Home 17 7 3 Diagnostic Process 17 7 4 Diagnostic Module 17 7 5 Configurations 17 8 Appendix 18 8 1 Included material 18 8 2 Order code 18 8 3 Order Information 18 ...

Page 4: ...2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Procedures can also be shown as numbers in brackets 1 Step no 1 2 Step no 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00he...

Page 5: ...autionary measures accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator is responsible for observing local prevailing safety regulations When defects and non clearable faults in the device occur take it out of service and secure against unauthorized use Approved use in ensured only...

Page 6: ...Mounting hole 2 EtherNet IP port 2 3 Display 4 Status LED Communication Module 5 Port 5 6 Pin Port LED Signal status 7 Port 6 8 Port 7 9 Port 8 10 Port 4 11 Port 3 12 Port 2 13 Port 1 14 Power Supply Port 15 Label 16 EtherNet IP port 1 17 Grounding connection 1 5 2 3 11 10 12 13 14 17 7 9 6 8 16 15 4 ...

Page 7: ...wer 2 24 V Input Power 3 0 V Input Power Common GND 4 0 V Output Power Common GND Note Provide sensor bus power and actuator power from separate power sources if possible Total current 9A The total current of all modules may not exceed 9A even when daisy chaining the actuator supply Grounding Note The FE connection from the housing to the machine must be low impedance and kept as short as possible...

Page 8: ...GND GND GND 4 Input Output 2A Input Output 2A 5 FE FE FE Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 Note Each output serves a maximum current of 1 6 amperes Total current of the module has to be lower than 9 amperes Note Unused I O port socket must be fitted with cover caps to ensure IP67 protection rating ...

Page 9: ... ports M12 A coded 8 x female Dimensions W x H x D in mm 68 x 224 x 37 9 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 670 gr 4 3 Operating conditions Operating temperature Ta Storage temperature 5 C 70 C 25 C 70 C EMC EN 61000 4 2 3 4 5 6 EN 55011 Severity level 2B 3A 4B 2B 3A Gr 1 CL B Shock vibration EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 EN 60068 2 64 4 4 Electric...

Page 10: ...shing Fixed busclock is not possible red green flashing Initial sequence Net off Module got no IP address green flashing Module got IP but no connection could be established green Connection established red flashing Connection timeout red green flashing Initial sequence 100 off Bus clock 10 Mbit s yellow Bus clock 100 Mbit s LNK green Data transfer Port Each Port has two two colour LEDs to indidca...

Page 11: ...and 3 on stated port 3 S7 S6 S5 S4 4 O22 O34 O22 O24 O12 O14 O02 O04 Overload status O04 Overload on port 0 pin 4 Only if port is configured as output 5 O72 O74 O62 O64 O52 O54 O42 O44 6 0 0 0 0 0 0 PS PA Power status PS Sensor power PA actor power 7 0 0 0 0 0 0 0 0 Reserved 5 3 Process Data Output BNI EIP 302 105 Z015 There are 6 bytes of output data Have a look at the tables below to see the map...

Page 12: ...0 O14 0 O04 Overload status O04 Overload on port 0 pin 4 Only if port is configured as output 3 0 O74 0 O64 0 O54 0 O44 4 0 0 0 0 0 0 PS PA Power status PS Sensor power PA actor power 5 0 0 0 0 0 0 0 0 Reserved 5 6 Process Data Output BNI EIP 202 105 Z015 There are 6 bytes of output data Have a look at the tables below to see the mapping of the process data outputs Byte Bit Description 7 6 5 4 3 2...

Page 13: ...ription 7 6 5 4 3 2 1 0 0 I32 I34 I22 I24 I12 I14 I02 I04 Input data I04 Input on port 0 pin 4 1 I72 I74 I62 I64 I52 I54 I42 I44 2 S3 S2 S1 S0 Short circuit status Short circuit between Pin 1 and 3 on stated port 3 S7 S6 S5 S4 4 0 0 0 0 0 0 PS PA Power status PS Sensor power PA actor power 5 0 0 0 0 0 0 0 0 Reserved 5 9 Process Data Output BNI EIP 104 105 Z015 There are 2 bytes of output data Have...

Page 14: ... of the control system If the lock is set editing isn t possible anymore see Bit layout chapter 8 Appendix 6 2 Adress Defaults IP Address 169 254 1 1 Subnetmask 255 255 255 0 Gatewayaddress 0 0 0 0 6 3 Controls and visualization 1 Display 2 Arrow Key 3 Octett Cursor 4 Address type cursor 5 Set Key 6 LED 6 4 Display information IP IP address SN Subnet address GW Gateway address 3 fourth octet 2 thi...

Page 15: ...IP 192 168 015 005 VERSION H W 1 0 S W 1 0 Subnet 255 255 255 000 Gateway 000 000 000 000 hard und firmware revision Current IP Current subnetmask e Current gatewayaddress BNI EIP 302 105 Z015 Module name B A L L U F F BALLUFF actual state change over S condition short time keypress on set key S condition long time keypress on setkey min 3 seconds condition short time keypress on arrow key IP CONF...

Page 16: ...entered address gets saved by short keypress on set value when editing first octet The entered value can immediately seen on the ip overview screen Manual changes of ip subnet or gateway results in automatic change to static in IP Setup Note To work with the new configuration the module needs a power down reset STATIC DHCP X FACTORY STATIC X DHCP FACTORY x STATIC DHCP FACTORY S S S S editing mode ...

Page 17: ... the screen is flickering If the module receives a single ping the word ping is shown in the display screen for a few seconds Afterwards the screen is reset to the screen which had been shown before By short time key press on set key the ping mode can be left preterm If the module receives a double ping the word ping is shown in the display This screen can be left only by short time key press on s...

Page 18: ...nformation about the configuration and network activity of the module At the top of the window you can see the navigation bar which allows you to switch between the different webpages just click on the corresponding text 7 3 Diagnostic Process On this page you can get some information about the module s current process data by having a look at the leds 7 4 Diagnostic Module On this page you can se...

Page 19: ...ctions 302 IP 67 Input Output Module 202 IP 67 Output Module 104 IP 67 Input Module Variants 105 Display version 2 port switch Mechanical version Z015 Material Die cast zinc housing Uplink 2 x M12x1 internal thread Power 7 8 external thread 7 8 internal thread Sensor Ports 8 x M12x1 internal thread 8 3 Order Information Product ordering code Order code BNI EIP 104 105 Z015 BNI004M BNI EIP 202 105 ...

Page 20: ...ff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 886817 E Edition 1208 Revised Edition 1111 2 Subject to modification ...