IO-Link interface (continued)
7.4
System commands
Different commands are implemented in the BMP that can
be reached via parameter
System Command
on
index 2,
subindex 0
. Once a system command is transmitted to the
BMP, the command triggers the desired action, provided
that this action is permitted in the current application state.
Command Name
Description
0x01 (1)
ParamUploadStart
Starts parameter upload.
0x02 (2)
ParamUploadEnd
Ends parameter upload.
0x03 (3)
ParamDownloadStart
Starts parameter download.
0x04 (4)
ParamDownloadEnd
Ends parameter download.
0x05 (5)
ParamDownloadStore
Completes the configuration and starts the data storage.
0x41 (65)
SP1 Single Value Teach
Saves the currently measured position as
Setpoint 1
.
0x42 (66)
SP2 Single Value Teach
Saves the currently measured position as
Setpoint 2
.
0x4E (78)
Teach Reset
Deletes the SP1 and SP2 values of all SSCs.
0x80 (128)
Device Reset
Re-initializes all device components.
0x82 (130)
Restore Factory Settings
Resets all configurations to the factory setting.
0xA5 (165)
Reset Maintenance
Resets all operating parameters.
0xE0 (224)
Teach Preset
Calculates and saves the PDV offset, sets the current output value to the preset
value.
0xE1 (225)
Teach Measurement
Range Lower Limit
Teaches in the current position as a lower limit value of the measuring range.
0xE2 (226)
Teach Measurement
Range Upper Limit
Teaches in the current position as an upper limit value of the measuring range.
Tab. 7-5: System commands of index 2, subindex 0
BMP 01-EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System