48
12.1 Troubleshooting
Error
Possible causes
Troubleshooting/explanation
The controller does not receive any
travel information.
The required supply voltage is not
available.
Check if there is any voltage and that the
BML is correctly connected.
The voltage drop in the supply line is
too large.
The magnetic encoder system must
receive a supply voltage of 18…30 V.
The sensor head is not properly
connected.
Check the pin assignment using the wiring
diagrams.
There is no IO-Link communication.
A flashing LED indicates active IO-Link
transmission. If this LED is not flashing,
check the connection.
The controller does not receive any
travel information at certain points
or an
incorrect position is output when
switched on.
The distance between the sensor head
and magnetic tape is incorrect (in some
places).
Adjust the height/angle of the sensor
head. To check, move the sensor head by
hand over the entire measuring range.
Some of the magnetic poles of the
magnetic tape are damaged
(mechanically damaged or due to
strong magnets).
Exchange the magnetic tape.
Non-linearity is outside the
tolerance.
The sensor head is not moving parallel
to the magnetic tape (for tolerances see
Section 4.3.3 and Section 4.3.4).
The distance/angle between the sensor
head and magnetic tape is too large.
Correctly position/orient the sensor head
A position substantially larger than
null is output near the start of the
magnetic tape
or,
during movement, the position value
jumps from 8 m to 0 m.
The measuring range was not set
correctly.
Move the sensor head to the beginning of
the area of travel and perform the start set
function there.
LED lights up/flashes red.
The sensor head function is disrupted
by incorrect installation or damage to
the magnetic tape.
Check for the correct installation of the
sensor head and the magnetic tape.
Check if the direction of the arrow on the
magnetic tape and sensor head matches.
Check whether the sensor head is being
operated within the limits defined in
Section 4. Check magnetic tape for
mechanical or magnetic defects.
During switch-on, the BML transmits
a position signal. After a short
movement, an error occurs (in the
plausibility check).
The orientation of the magnetic tape is
incorrect, the working space is not
being maintained, or the magnetic tape
is damaged.
Check for the correct installation of the
sensor head and the magnetic tape.
Check if the direction of the arrow on the
magnetic tape and sensor head matches.
The direction of the 1Vpp signal and
absolute value do not match.
Check the controller configuration;
change if necessary.
If necessary, change the controller
configuration or real-time signal count
direction by swiA and –A or +B
and –B.
12
Appendix
BML SL1-ALZ _ -U_ ZZ- _ U1L - _ _ _ _
Absolute magnetic encoder system
english
Summary of Contents for BML SL1-ALZ-U-ZZ-U1L Series
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Page 4: ...www balluff com...
Page 52: ......
Page 53: ...english User s Guide BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Page 54: ...www balluff com...
Page 102: ......
Page 103: ...fran ais Notice d utilisation BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Page 104: ...www balluff com...
Page 152: ......
Page 153: ...italiano Manuale d uso BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Page 154: ...www balluff com...
Page 202: ......
Page 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Page 204: ...www balluff com...