www.balluff.com
BMF 235
Sensor family
9
4
Assembly and connection
5.
Mark the position of the magnet (center of the
magnet).
6.
Mount the sensor in the center between the two
marks (sensor groove).
4.2 Mounting the sensor
– Allen wrench, 2.0 mm: max. torque 0.4 Nm
– Screwdriver, 4×0.8 mm: max. torque 0.4 Nm
4.3 Connecting the sensor
Sensor pin configurations
(view onto the contact pins)
Function of the pins and strands for cable connection
Pin/strand color
Signal
2
1
4
3
Class A
M 8
2
1
4
3
Class A
M 12-4
Pin 1/brown
+24V (supply voltage UB+)
Pin 2/white
OUT2 (switch output S2) or DIO for IO-Link
Pin 3/blue
GND (operating voltage UB-; reference potential)
Pin 4/black
OUT1 (switch output S1) or C/Q for IO-Link
The sensor features overload protection.
The sensor is functional again after the overload has been eliminated.
0.9
max. 0.07 Nm