Remote Lock/Unlock Input
The remote lock feature allows the user to lock out the local controls (keys) to prevent operators from
making unauthorized adjustments. This signal line must be connected to VDC to lock the sensor. This line
may be left unconnected if the lock feature is not used. While the sensor is locked, pressing either
P/-
or
T/+
will result in
rL
(
r
emote
L
ock) indication on the display.
Spot size table
Part Number
BLT 31M-001-U-S92
BLT 31M-002-U-S92
Part Number
BLT 31M-001-U-S92
BLT 31M-002-U-S92
Nominal Sensing
100 mm
300 mm
Nominal Sensing
100 mm
300 mm
Spot Diameter *
Spot Diameter w/ 50 mm lens * (BLT 31M-PK-1)
20 mm distance
18 mm
18 mm
20 mm distance
8 mm
8 mm
50 mm distance
6 mm
6 mm
38 mm distance
2 mm
2 mm
100 mm distance
5 mm
5 mm
50 mm distance
4 mm
4 mm
150 mm distance
4 mm
75 mm distance
8 mm
8 mm
200 mm distance
8 mm
100 mm distance
13 mm
13 mm
250 mm distance
15 mm
150 mm distance
22 mm
300 mm distance
16 mm
350 mm distance
18mm
* All sizes are approximate
Display Indicators
Indicators
•
Green LED
Threshold Mode while in Undetect
•
Red LED
Detect
•
Yellow LED
Threshold Mode while in Detect
•
Green LED blinking
Teach Undetect
•
Red LED blinking
Teach Error
•
Yellow LED blinking
Teach Detect
T/+
P/-
Display decimal points
•
None illuminated LED low intensity
•
One illuminated LED medium intensity
•
Two illuminated LED high intensity
M12 connector pin assignments
M12 Connector
Wire Color
Description
Pin 1
Brown
Power 10 to 24VDC
Pin 2
White
Discrete output, PNP/NPN, NO/NC
Pin 3
Blue
Ground
Pin 4
Black
Analog output 0 to 5V DC
Pin 5
Gray
Remote LOCK / UNLOCK input
PNP/NPN
LOCK/UNLOCK
BN 1
WH 2
GY 5
BK 4
BU 3
+
-
www.balluff.com - 1-800-543-8390