Balluff BLT 31M Operating Instructions Manual Download Page 3

Cautions and Warnings 

 

 

Caution:  

The discrete output must not be connected to outputs from other sensors (i.e. outputs 
from multiple sensors must not be connected in parallel).  Parallel connections may 
damage sensor output circuitry.  

 
Langue Française Attention: 

 

La LED UV rayonne la lumière UV intense lors du fonctionnement.  
N'examinez pas directement la lumière UV lors du fonctionnement de dispositif. Ceci 
peut être nocif aux yeux, même pour la brève période due à la lumière UV intense.  
Si le visionnement de la lumière UV est nécessaire, employez svp les verres filtrés UV 
pour éviter des dommages d'oeil par la lumière UV.  
 
• Évitez l'exposition directe d'oeil à la lumière UV. Subsistance hors de l'extension des 
enfants.  

 
 

Certifications 

 

 

 

 

www.balluff.com  - 1-800-543-8390 

 

 

 

3   

Summary of Contents for BLT 31M

Page 1: ...BLT 31M 850196 VER 03 H21 Subject to modification Replaces edition 0708 ALTENDORFR ORD 0777 Luminescence Sensors Operating Instructions www balluff com 1 800 543 8390 1...

Page 2: ...isis Level H 6 Discrete Output Configuration 6 Caution 6 Extend Output Pulse P 6 Null Offset nu 7 Gain Adjustment r 7 Teach Function 7 Input Output Signals 7 Discrete Output 7 Analog Output 7 Remote L...

Page 3: ...umi re UV intense lors du fonctionnement N examinez pas directement la lumi re UV lors du fonctionnement de dispositif Ceci peut tre nocif aux yeux m me pour la br ve p riode due la lumi re UV intense...

Page 4: ...ve intensity from 00 to 50 Easy two step sensitivity and 3 LED intensity settings provide for flexible operation over wide range of distances and materials Specifications UV light source 370nm UV LED...

Page 5: ...d yellow and green on the status LED located above the display Intensity display mode During normal operation the sensor display will indicate the relative intensity of a target within its field of vi...

Page 6: ...allows the out put to re main activated until th e level dro ps significantly Press and release the T key to change the hysterisis setting The default setting is 2 Discrete Output Configuration This...

Page 7: ...teach function and return to the normal operating mode by Pressing the T key for several seconds When in the teach mode the LED flashes constantly yellow green or red Yellow indicates that the sensor...

Page 8: ...mm distance 5 mm 5 mm 50 mm distance 4 mm 4 mm 150 mm distance 4 mm 75 mm distance 8 mm 8 mm 200 mm distance 8 mm 100 mm distance 13 mm 13 mm 250 mm distance 15 mm 150 mm distance 22 mm 300 mm distan...

Page 9: ...et M12 5 pin Connector straight cable 5 m Caution The BLT 31M PK 1 lens extends 0 015 beyond the back surface of the BLT 31M Luminescence Sensor Note In some cases it may be necessary to mount the BLT...

Page 10: ...nada Inc 2840 Argentia Road Unit 2 Mississauga Ontario L5N 8G4 Phone 905 816 1494 Toll free 1 800 927 9654 Fax 905 816 1411 E mail balluff canada balluff ca Mexico Balluff de Mexico S A de C V Prol Av...