www.balluff.com
BIS U-602_ Processor Unit
TCP/IP / RS232
45
The operating states of the identification system and the TCP/IP connection are indicated by
LEDs.
Figure 5:
10
13
12
11
8
9
5
2
1
3
4
7
6
Function indicators
Identification system
1
Ready
/
Error
2
Tag operating
3
Tag present
4
TCP/IP ready (BIS U-6027 only)
5
TCP/IP connected (BIS U-6027 only)
6
Digital input 2
7
Digital input 1
8
Digital input 1
9
Digital input 2
10
Digital input 3
11
Digital input 4
12
Transmit data (TxD)
13
Receive data (RxD)
The "Ready
/
Error" status LED flashes green during the start-up phase.
When setup is finished and the system is ready for operation, the "Ready
/
Error" status LED
lights up green.
Identification system
Status LED
Meaning
Ready
/
Error
Off
Not ready
Illuminated green
Ready
Flashing green
Setup
Flashing red
Error (e.g. device error or broken cable)
Tag operating
Off
No command
Illuminated orange Command to data carrier (e.g. detection, read or write)
8.6 Displays
Start-up phase
Diagnostics
8
Device Function
Summary of Contents for BIS U-6020-053-10 RS232