44
2
2.6.3 Installing the BIS M-626-069-A01-06_
Industrial Ethernet (IND)
Figure 29 - IND Typical Layouts
The BIS M-626-069-A01-06_
Processor unit is designed for Industrial Ethernet IP
RFID applications, where the processor unit is connected in an
Industrial Ethernet (IND)
TCP/IP network via compatible cables through a hub or directly to an
Industrial Ethernet
(IND)
host.
1.
Select a suitable location for the BIS M-626_ Processor unit/Antenna.
2.
Mount the BIS M-37_ antenna to the BIS M-626_ Processor unit, either directly or
remotely, as described in par. 2.2.
3.
Mount the processor unit and antenna to your mounting fixture using
M5 (or #10)
diameter screws (
not included
) and secure them with appropriate washers and nuts.
Tighten screws to
1.7 Nm or 15 lbs per inch ± 10%
.
4.
Connect the BCC0CT1 M12 4-pin male connector to the M12 4-pin female interface
connector on the BIS M-626_. Connect the BCC0CT1 RJ45 male connector to the LAN
hub/switch. If connecting directly to the host computer you will need to use an additional
crossover cable.
5.
Build a power supply cable using the BCC06ZF M12 5-pin female connector. Use
minimum 24 AWG wires for connection to the power supply lines according to the Vdc
connector pinout. Connect the BCC06ZF M12 5-pin female connector to the M12 5-pin
male connector on the processor unit. Connect the other end of the cable (wires or user-
supplied connectors) to the power supply.
6.
Apply power to the processor unit after all cable connections have been made. The LEDs
on the unit will flash. The READY LED is ON after the power up sequence has
completed. Then one of the
Industrial Ethernet (IND)
Address LEDs will remain on,
either Default or
Custom.
To verify operations, download the
Balluff Dashboard™ Configuration Tool from
. The
Balluff Dashboard™ Configuration Tool allows users to configure and
control their BIS M-626-069_ processor units and send RFID commands for testing
purposes.
See the Dashboard™ Manual for details.
BCC06ZF
B
IS
M
-6
2
6
-0
6
9
_
w
a
n
te
n
n
a
to Power Supply
BCC0CT1
E
th
e
rn
e
t
Ro
u
te
r
PLC
Vdc
GND
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...