BIS M-62_ REFERENCE MANUAL
180
11
11.2 BIS M-37_ ANTENNAS
RADIO FEATURES
Frequency
13.56 MHz
Input Impedance
50 ohms
Gain:
BIS M-370-000-A02
-37.8 dBi
BIS M-371-000-A01
-36.6 dBi
BIS M-372-000-A01
-26.3 dBi
BIS M-373-000-A01
-22.9 dBi
Conducted Input Power
1 W
ENVIRONMENTAL FEATURES
Operating Temperature
-20° to +50 °C (-4° to +122 °F)
Storage Temperature
-20° to +70 °C (-4° to +158 °F)
Humidity max.
90% non condensing
Protection Class EN 60529
IP65 (when correctly mounted)
PHYSICAL FEATURES
BIS M-370-000-A02
Dimensions
70 x 500 x 40 mm (2.76 x 19.69 x 1.57 in)
Weight
635 g (22.4 oz)
BIS M-371-000-A01
Dimensions
100 x 100 x 42 mm (3.94 x 3.94 x 1.67 in)
Weight
280 g (9.88 oz)
BIS M-372-000-A01
Dimensions
200 x 200 x 42 mm (7.87 x 7.87 x 1.67 in)
Weight
500 g (17.64 oz)
BIS M-373-000-A01
Dimensions
300 x 300 x 42 mm (11.81 x 11.81 x 1.67 in)
Weight
740 g (26.10 oz)
The BIS M-62_ Processor units and its antenna are intended for indoor use only.
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...