DEVICENET INTERFACE
115
8
8.2.3 Configuring Data Rate and Node Address
As noted, each device, computer and controller on a DeviceNet network is considered an
individual node for which a unique
Node Address
number (between 0 and 63) is assigned.
The node address provides a means of numerically identifying each device on a DeviceNet
network.
Prior to operating the BIS M-623-071-A01-03-ST30 , you must verify that it has been
configured for the same Data Rate as your network and that it has been assigned a suitable
node address value. The Controller supports data rates of 125Kb (default), 250Kb and
500Kb and supports node addresses 1
– 63 (default: 63).
To change the data rate or node address, use either the "
Node Commissioning
" tool in
RSNetWorx for DeviceNet
or the “Balluff Dashboard™” utility running on a host computer
that is connected to the RS232 port on the Controller. The
Balluff Dashboard™
utility is
available on the Balluff Web site (www.balluff.com).
NOTE
When using node commissioning in RSNetWorx for DeviceNet, modify only
one parameter at a time (either data rate or node address). After changing
the data rate, you must manually cycle power to your DeviceNet network for
the change to take effect.
Factory Default Configuration
:
Data Rate
= 125Kb
Node Address
= 63
Summary of Contents for BIS M-370-000-A02
Page 1: ......
Page 2: ......
Page 3: ......
Page 7: ......
Page 16: ...9 BIS M 371 000 A01 BIS M 372 000 A01 BIS M 373 000 A01 BIS M 370 000 A02 Figure G...
Page 17: ...10...
Page 21: ...BIS M 62_ MANUAL 14 1...
Page 60: ...INSTALLATION 53 2...
Page 77: ...BIS M 62_ MANUAL 70 4...
Page 101: ...BIS M 62_ MANUAL 94 5...
Page 103: ...BIS M 62_ MANUAL 96 6 The HTTP Server Main Page will be displayed...
Page 126: ...DEVICENET INTERFACE 119 8...
Page 185: ...BIS M 62_ MANUAL 178 10...
Page 188: ...RFID OPERATING PRINCIPLES 181 11...