www.balluff.com
7
3 Installation
3.5. 180° rotation of
the connector
insert
The connector insert on the base and remote can be rotated 180°.
Follow the disassembly steps described below (steps 1 to 6). After the connector insert is
rotated (step 7), subsequent reassembly is performed in reverse order.
Removing the
holder
1. Loosen the grub screw
2. Pull off the BIC holder
3. Loosen the two countersunk screws
4. Remove the BIC base
5. Pull out the safety pin
6. Slide out the connector insert
7. 180° rotation of the connector insert
Note
The disassembly/assembly for rotating the connector can be carried out only
2 times. (construction conditioned)