www.balluff.com
43
english
7.1
General data
Function
Vibration velocity
Vibration acceleration
Vibration severity zones
Contact temperature
Relative humidity
1)
Ambient pressure
1)
Sensor self-awareness
Approval/Conformity
CE
7.2
Functional safety
MTTF (40 °C)
239 a
7.3
Detection range/Measuring range
Contact temperature
Measuring range
0…70 °C
Resolution
0.1 °C
Measurement error
±2% FS
Non-linearity
±0.75% FS
Settling time
5 min
Relative humidity
Measuring range
5…95% RH
Resolution
1% RH
Non-linearity
±2.5% FS
Settling time
5 min
Ambient pressure
Measuring range
300…1100 hPa
Resolution
0.15 hPa
Non-linearity
±0.1% FS
Vibration (general)
Frequency range
2…3200 Hz
Sampling rate
6400 Hz
Measuring principle
MEMS
No. of measurement axes
3
1)
1)
Vibration velocity
RMS measuring range
0…220 mm/s
2)
RMS resolution
0.42 mm/s
2)
RMS measurement error
±5% FS
2)
RMS Non-linearity
±2% FS
2)
Evaluation variables (per
measurement axis)
RMS
Peak to peak
Mean
Standard deviation
Crest factor
Skewness
Kurtosis
Vibration acceleration
RMS measuring range
0…16 g
RMS resolution
0.006 g
2)
RMS measurement error
±5% FS
2)
RMS Non-linearity
±2% FS
2)
Evaluation variables (per
measurement axis)
RMS
Peak to peak
7.4
Ambient conditions
Ambient temperature
0…70 °C
Storage temperature
–20…+70 °C
Degree of protection
IP67
IP68
3)
IP69K
3)
1)
only for the BCM R15E-
002
-DI00-_ _ , _-S4
2)
at 79.4 Hz
3)
only for BCM R15E-
001
-DI00-_ _ , _-S4
7
Technical data
BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
Summary of Contents for BCM R15E-00 Series