www.balluff.com
12
Analog output (X4)
A 16 bit analog output is available at terminal X4 pin 1, 2 and 3.
This output can be configured and scaled in the ANALOG MENU.
The following configuration is possible:
•
Voltage output:
-10 … +10 V
•
Current output:
0 … 20 mA
•
Current output:
4 … 20 mA
The analog output is proportional to the display value and is referenced to potential
AGND.
AGND and GND are internally interconnected.
Important:
A parallel operation with voltage and current output at the analog output is
not allowed.