MN715J
Receiving and Installation 3-21
Process Control Connection
Figure 3-15 Process Control Connection Diagram
11
12
13
14
15
16
17
18
Forward
Reverse
Process/CMD Select
Jog Forward
Jog Reverse
Fault Reset
External Trip
Input Common
Refer to Figure 3Ć9.
J4
See recommended terminal
tightening torques in Section 6.
J4-11
OPEN motor decels to stop (depending on Keypad Stop mode).
CLOSED starts Forward motor rotation.
J4-12
OPEN motor decels to stop (depending on Keypad Stop mode).
CLOSED starts Reverse motor rotation.
Note: Simultaneous closure of J4-11 and J4-12 will cause the motor to regen to stop
(not coast).
J4-13
OPEN selects the input specified in the Level 1 Input block,
ANA CMD Select parameter.
CLOSED selects the closed loop feature of the Process Control mode.
Note: The process will run in one direction. For example, if the forward line (J4-11)
is closed, the process will only run in the forward direction. The PID algorithm
will not reverse the direction automatically.
J4-14
OPEN allows normal operation.
CLOSED jogs the motor in the forward direction.
J4-15
OPEN allows normal operation.
CLOSED jogs the motor in the reverse direction.
Note: Simultaneous closure of J4-14 and J4-15 selects jog forward.
J4-16
OPEN allows normal operation.
CLOSED to reset a fault condition.
J4-17
If J4-17 is connected, you must set Level 2 Protection block, External Trip to
“ON” to activate the opto input.
OPEN causes an external trip fault. The control will disable and the motor
coasts to a stop. An external trip fault is displayed (also logged in the fault log).
CLOSED allows normal operation.
Summary of Contents for ID15J101-ER
Page 1: ...Series 15J Inverter Control 7 04 MN715J Installation and Operating Manual ...
Page 5: ...iv Table of Contents MN715J ...
Page 11: ...2 4 General Information MN715J ...
Page 59: ...4 22 Programming and Operation MN715J ...
Page 75: ...6 6 Specifications and Product Data MN715J ...
Page 79: ...A 4 Dynamic Brake Hardware MN715J ...
Page 86: ...Appendix C Remote Keypad Mounting Template MN715J Remote Keypad Mounting Template C 1 ...