9
R. 07/22 SB3115
Balcrank™ Corporation · Weaverville, NC 28787 · 800-747-5300 · 800-763 0840 Fax · www.balcrank.com
EN
EN
CONFIGURATION MENU
8.
The calibration of valve anticipation factor is performed by
dispensing 0.26 gal (1 liter) at the working flow rate. This
preset configuration will already appear on the display:
9.
Press AUTO and then start dispensing. When the preset
0-26 gal (1 liter) is reached, the gun will automatically
calibrate the anticipation by displaying the new value on
the screen. The display shows “done” and automatically
returns to the main menu.
MANUAL SET OF CALIBRATION FACTOR
5.
Confirm the selection by pressing the “ON” button, the
display returns to the main menu. Pressing the “ON”
button again exits the configuration menu.
Manual calculation of calibration factor can be
made with following equation:
1.
Simultaneously press the “ON” and “SELECT” buttons
until the setup menu is displayed..
3.
Press and hold “SELECT” until “Cfactr” flashes in
second line and the current calibration factor is
displayed.
2.
Press “SELECT” until the next menu is displayed.
4.
Set the value of the new calibration factor. Pressing the
“0.1” quantity button increments the units and the “10”
button decrements the units.
Calibration factor calculation
Factor
=
quantity shown on tdisplay
x 1000
actual quantity dispensed
Fig. 14
Fig. 15
Fig. 16
Fig. 17