STRAINER MAINTENANCE

TECHNICAL SPECIFICATIONS

WARNING: 

Release all pressure within the system 

and disconnect the air supply to the pump prior to 
performing strainer replacement. Discharge pressure 
operating the gun into an appropiate container and 
open any bleeder-type air valves and fluid drain 
valver in the system if necessary.

The gun can be provided with a strainer (optional). To 
inspect strainer or make replacement read the 

 

following procedure:
•  Remove the cover (1) of the swivel and loosen the nut (2) 

of the hose.

•  Remove the o-ring (3), (4) and then the filter.
•  Check the filter clean or replace as necessary. 
•  Place again the filter with the o-ring and install the hose 

with the swivel cover.

!

Thread port

½” NPT

Moist parts materials

Acetal, stainless steel, NBR, aluminum, brass, zinc plated steel

Meter type

Oval gear

Flow rate

0.25 - 7.5 US gal/min (1-30 l/min)

Maximum pressure

1450 psi (100 bar)

Temperature range

14 a 122 ºF (-10 a 50 ºC)

Accuracy (oil)

±0,5 %

Accuracy (coolant solutions)

±1 %

Viscosity range

Up to 2000 mPa.s

Display

LCD with double row digits

Units

Litres, galons, quarts, pints

Batteries

4 x AA 1.5V

Weight (with nozzle and batteries)

4.6 lb (2.1 kg)

Dimensions (without nozzle tube)

11.7” x 3.5” x 6.1”  (297 x 89 x 155 mm) (length x width x height)

4

1

3

2

Summary of Contents for 3331-031

Page 1: ...800 747 5300 800 763 0840 Fax www balcrank com Part No C d 3331 031 Preset Rigid 3331 032 Preset Flex 90 3331 033 Preset Bare PRESELECTION GUN BASIC 2 PISTOLA DE PRESELECCI N BASIC 14 EN ES Parts and...

Page 2: ...age If using a rigid nozzle first tighten the nut 1b place in proper position the nozzle tuve 2 and then tighten the nut 3 to secure it INTRODUCTION opening it to avoid that acid get sprayed onto your...

Page 3: ...ten the screws 2 4 Finally mount the rubber protector 1 The control gun turns off automatically after 30 seconds of inactivity to save energy To switch on again the display press the ON button 4 The d...

Page 4: ...ed press the AUTO button The AUTO indicator lights up on the display the partial counter is reset to zero and the preset quantity is shown on the bottom line fig 2 The gun is already prepared to start...

Page 5: ...presets are numbered from 0 to 9 To select these predefined presets follow the process below NOTE Before activating the preset mode make sure the trigger is not pulled 1 Press the SELECT button The di...

Page 6: ...en after about 3 seconds Pressing the SELECT button allows navigation through the various menu functions Main dispensing screen ON SELECT PRESS Memorized presets configuration Calibration Also allows...

Page 7: ...ero value stored will be visible so you can manage the presets needed The preset pr 0 is the only one that cannot be set to zero so it will always be visible 2 Press and hold SELECT until the followin...

Page 8: ...aching the preset value the dispensed quantity exceeds the allowed accuracy above the preset value Press ON to not calibrate the anticipation you will 6 Press SELECT to confirm The display will show d...

Page 9: ...UAL SET OF CALIBRATION FACTOR 5 Confirm the selection by pressing the ON button the display returns to the main menu Pressing the ON button again exits the configuration menu Manual calculation of cal...

Page 10: ...SELECT until FCLOSE flashes on second line and the current factor is displayed 5 Press ON to save the new value and return to the main menu 2 Press SELECT until the following screen is displayed 4 The...

Page 11: ...ts are displayed 5 Confirm the selection by pressing the ON button the display returns to the main menu Pressing the ON button again exits the configuration menu 1 Press and hold SELECT until the foll...

Page 12: ...over 1 of the swivel and loosen the nut 2 of the hose Remove the o ring 3 4 and then the filter Check the filter clean or replace as necessary Place again the filter with the o ring and install the ho...

Page 13: ...gger desactivate AUTO mode and re activate it making sure that the trigger is not depressed Accuracy error Very high or low flowrates used Calibrate Very high or low water based fluid fluid viscosity...

Page 14: ...ectamente el tubo de la extensi n 2 y a continuaci n apriete la tuerca 3 para dejarla fija INTRODUCCI N En caso de contacto con el l quido liberado por la pila enjuague inmediatamente con agua limpia...

Page 15: ...ola se apaga autom ticamente trascurridos 30 segundos de inactividad para ahorrar energ a Para encender la pantalla pulse el bot n de encendido 4 La pantalla muestra el contador parcial 1 1 en la fila...

Page 16: ...e ilumina el indicador AUTO el contador parcial se pone a cero y en la l nea inferior se muestra la cantidad preseleccionada Fig 2 La pistola queda a la espera de iniciar el dispensado 3 Durante el di...

Page 17: ...reselecciones m s usadas habitualmente Estas preselecciones se numeran de la 0 a la 9 Para seleccionar estas preselecciones predefinidas siga el siguiente proceso NOTA Antes de activar la preselecci n...

Page 18: ...bot n SELECT permite la navegaci n por las distintas funciones del men Pantalla inicial de dispensado PULSACI N SIMULT NEA ON SELECT Men de ajuste de preselecciones m s usadas Calibraci n mediante re...

Page 19: ...almacenado alg n valor distinto de cero de esta manera puede controlar el n mero que desea emplear La preselecci n pr 0 es la nica que no se puede poner a cero por lo que siempre estar visible 2 Mante...

Page 20: ...eleccionado la cantidad dispensada excede por encima del error permitido dicho valor Pulse ON para no calibrar la anticipaci n regresar al 6 Pulse SELECT para confirmar La pantalla mostrar done junto...

Page 21: ...RACI N 5 Confirme la selecci n pulsando el bot n ON la pantalla vuelve al men principal Una nueva pulsaci n del bot n ON sale del men de configuraci n El c lculo manual del factor de calibraci n puede...

Page 22: ...e procedimiento 3 Mantener presionado SELECT hasta que FCLOSE parpadea en segunda l nea y se muestra el valor actual 5 Pulse ON para guardar el nuevo valor y regresar al men principal 2 Presione SELEC...

Page 23: ...muestran las unidades actuales 5 Confirme la selecci n pulsando el bot n ON la pantalla vuelve al men principal Una nueva pulsaci n del bot n ON sale del men de configuraci n 1 Mantenga pulsado SELECT...

Page 24: ...afloje la tuerca 2 de la manguera Extraiga la junta t rica 3 que fija el filtro 4 y a continuaci n el filtro Revise el filtro y proceda a su limpieza o sustituci n en caso necesario Fije de nuevo el f...

Page 25: ...pistola Caudal bajo Filtro sucio o da ado Limpie o sustituya el filtro Presi n de bomba insuficiente Suba la presi n de la bomba Cantidad dispensada excede la cantidad preseleccionada de manera excesi...

Page 26: ...26 SB3115 R 07 22 Balcrank Corporation Weaverville NC 28787 800 747 5300 800 763 0840 Fax www balcrank com NOTES NOTAS...

Page 27: ...27 R 07 22 SB3115 Balcrank Corporation Weaverville NC 28787 800 747 5300 800 763 0840 Fax www balcrank com NOTES NOTAS...

Page 28: ...n Weaverville NC 28787 800 747 5300 800 763 0840 Fax www balcrank com For Warranty Information Visit www balcrank com Balcrank Corporation Weaverville NC 28787 800 747 5300 800 763 0840 Fax www balcra...

Reviews: