Your system has a 24-hour circ pump. The circ pump
and the ozone generator run continuously.
Warm/Cool (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set at 100F°/37°C. The last
measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is
current only when the circ pump has been running for at
least 2 minutes.
To display the set temperature, press the “Warm” or “Cool”
pad once.
To change the set temperature, press the pad a second time before
the LCD stops flashing. Each press of the “Warm” or “Cool” pad
will continue to either raise or lower the set temperature.
After three seconds, the LCD will stop flashing and display the
current spa temperature.
Jets 1
Touch the “Jets 1” button once to turn pump 1 on or off, and
to shift between low and high speeds (if equipped). If left
running, the low speed of the pump will automatically turn off
after 4 hours, and the high speed will automatically turn off after
15 minutes.
Jets 2
(If equipped)
Touch the “Jets 2” button once to turn pump 2 on or off. If left
running, pump 2 will automatically turn off after 15 minutes.
Blower
(If equipped)
This button is used to turn the blower on and off. If left on, the
blower automatically turns off after 15 minutes.
Light
Press the “Light” button to turn the light on and off. If left on,
the light automatically turns off after 4 hours.
(over)
VS510S/GS510S Control Reference Card
Circ Operation
Initial Start-up
When your spa is first actuated, it will go into Priming mode, indicated by “
.”
Please see the M-7 Installation Instruction Manual
for complete instructions on Power-up and Pump Priming
.
The Priming mode will last for less than 5 minutes (press “Warm” or
“Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.
Mode
Mode is changed by pressing the “Warm” or “Cool” button, then
pressing the “Mode” button.
Standard Mode
is programmed to maintain the desired
temperature. Note that the last measured spa temperature
displayed is current only when the circ pump has been running
for at least 2 minutes. “
” will be displayed momentarily
when you switch into Standard Mode.
Economy Mode
heats the spa to the set temperature only
during filter cycles. “
” will display solid when temperature
is not current, and will alternate with temperature when
temperature is current.
Sleep Mode
heats the spa to within 20°F/10°C of the set
temperature only during filter cycles. “
” will display
solid when temperature is not current, and will alternate with
temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is energized.
The second filter cycle begins 12 hours later. Filter duration is
programmable for 2, 4, 6, 8 hours or for continuous filtration
(indicated by “
”). The default filter time is 2 hours.
To program, press “Warm” or “Cool”, then “Jets 1”.
Press “Warm” or “Cool” to adjust. Press “Jets 1” to
exit programming.
At the beginning of each filter cycle the blower purges for
30 seconds; the pumps purge for 5 minutes. The only effect
filter duration has is: 1) During the filter, the circ pump never
turns off, and 2) In Economy and Sleep Modes, heating only
occurs during the filter cycle.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C
within the heater, the pumps and blower will automatically
activate to provide freeze protection. The equipment stays on
until 4 minutes after the sensors detect that the spa temperature
has risen to 45°F/7.2°C or higher. In colder climates, an
optional additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard sensors.
Aux freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and without a
4-minute delay in turnoff. See your dealer for details.