background image

Installation P/N 73-200-8501, Rev. B, 12/09/2020     Page 

1

 of 

4

 

Installation Instructions for Licensed Electricians, Plumbers, 

and Spa Technicians 

All components are intended to be installed and tested by a licensed electrician who is experienced in spas 
and  hot  tubs. A  properly installed  GFCI  and  grounding  must  be  installed with  any system.    Installation 
must be permitted and inspected prior to use. 

Any  sales  or  technical  advice  provided  on the  Spaguts.com website  or  by  Spaguts.com staff  shall  not  be 
construed to authorize or suggest anything but professional installation. 

Balboa brand VS501Z Spa Controller Kit 

Parts Content: 

(1) Balboa brand VS501Z Spa Controller w/ M7 5.5KW Flo-Thru Heater, P/N G5152 

(1) Topside Panel, VL200 Model w/ 7ft cable and 8-wire phone-type connector (Note that a topside substitution may be provided) 

(1) Topside Overlay, P/N 11095 (Overlay may be pre-installed on topside panel) 

(1) Topside Adapter Plate, P/N 11718 

(2) Heater Split Nuts, 2 inch, P/N 40-350-5421 (installed on each end of heater) 

(2) Heater Tailpieces, 2 inch, P/N 25-350-1052 (installed on each end of heater) 

(2) Heater O-Ring Gaskets, 2 inch, P/N 25-350-4030 (installed on each end of heater) 

(1) System Wiring Diagram, Labeled VS501Z – PN G5152 (attached to inside controller cover) 

(1) Double-Sided Operation Guide with Diagnostic Messages, 500Z Series, P/N 40789 

(1) Installation Instructions, P/N 73-200-8501 

(1) Light Harness, 2-Prong Amp Plug, Light Socket, 8ft Cable 

(1) Light Bulb, Clear, 12V 12W 

(1) Pump Cord, 4ft, 4-wire, 14 AWG, w/ 4-Prong Amp Plug, P/N 15-150-3060 

(2) Pump Cord, 4ft, 3-wire, 14 AWG, w/ 4-Prong Amp Plug, P/N 15-150-0024 

Plumbing up the system: 

This system will work if the pump draws or discharges water through the heater. 

Minimum water flow required is 25 GPM

Minimum 

plumbing size required is 1.5 inch

. This system is equipped with M7 Technology (no pressure switch). There are dual sensors installed 

on the heater to measure the water temperature flowing through the heater. No need to mount any sensors or flow switches. The heater has 
standard 2.0 inch plumbing fittings. If the spa plumbing is 1.5 inch, use reducers to connect to the heater 2.0 inch heater tailpieces. If re-
plumbing  is  necessary,  use  PVC  Glue  with  primer  to  connect  the  plumbing.  When  installing  an  In-Line  Filter  System,  either  install  it 
before the heat pump and controller or after the heat pump and controller. Never install the filter system in between the heat pump and 
controller.  Make  sure  to  create  a  water  flow  bypass  plumbing  around  the  filter  for  sufficient  water  flow.  For  systems  installed  near  or 
above the water level, and more than 5 feet from the tub, install the In-Line Filter System after the heat pump and controller with a water 
flow bypass plumbing. A water flow bypass plumbing allows half the water to go through the filter and half the water to go around the 
filter. This  way  water  flow  is  not  restricted. We  recommend  NSF  rated  flexible  PVC  for  simpler  connections.  Go  to this  link  for  more 
info

http://www.spaguts.com/Product.aspx?ID=42

.

 

 

Wiring Instructions: 

*110V Power Supply, 60Hz 

*Minimum 20A Power Supply is required. Use Copper Conductors Only. See wiring diagram for more information. 

Please  note  that  this  Installation  requires  3  dedicated  wire  connections  to  the  power  terminal  block  (TB1)  on  the  Circuit  Board. These 
include 

Line  1

Neutral

  and 

Ground

.  Connect  Hot  wire  to  Line  1  terminal.  Connect  Neutral  wire  to  Neutral  terminal.  If  a  dedicated 

Neutral  wire  is  not  connected,  the  heater  will  never  come  on  and/or  the  system  will  not  operate  properly. 

For  110V  operation

,  add  a 

jumper wire from terminal J11 to terminal J32 (SEE WIRING DIAGRAM FOR VERIFICATION).  If this jumper wire is not installed, 

Reviews: