19

TP700 

USER GUIDE   

     

42370 Rev A

18

Balboa Water Group   |   Your Single Source Solution

          FILTRATION AND OZONE

If your spa does not have a circulation pump, pump 

1 low and the ozone generator will run during a filter 

cycle. If your spa has a circulation pump, the ozone will 

run with the circulation pump.
Many control systems are factory-programmed with 

one filter cycle that will run in the evening (assuming 

the time-of-day is properly set) when energy rates 

are often lower. The filter cycle time and duration are 

programmable (view page 14). A second filter cycle can 

be enabled as needed.
At the start of each filter cycle, any additional water 

devices (such as pumps and blower) will also run briefly 

to purge its plumbing to maintain good water quality. 

          FREEZE PROTECTION

If the temperature sensors within the control system’s 

heater detect a low enough temperature, then the 

pump(s) and the blower automatically activate to 

provide freeze protection. The pump(s) and blower will 

run either continuously or periodically depending  

on conditions.
In colder climates, an optional additional freeze sensor 

may be added to protect against freeze conditions that 

may not be sensed by the standard sensors. Auxiliary 

freeze sensor protection acts similarly except with the 

temperature thresholds determined by the switch. See 

your dealer for details.

          CLEANUP CYCLE  (Optional)

When a pump or blower is turned on by pressing 

a button on the panel, a clean-up cycle begins 30 

minutes after the pump or blower is turned Off or times 

out. The pump and the ozone generator will run for 30 

minutes or more, depending on the control system. 

On some control systems, you can change this setting 

(view page 29). 

          PUMPS

Press the 

JETS

 button once to turn Pump 1 On or 

Off, and to shift between low-speed and high-speed 

if equipped. If left running, Pump 1 will turn Off after a 

time-out period.
If your spa does not have a circulation pump, Pump 

1 will run at low speed when the blower or any other 

pump is on. 
If the spa is in Ready Mode (view page 22), Pump 1 

low may also activate for at least 1 minute every once 

in a while to detect the spa temperature (polling) and 

then to heat to the set temperature if needed. When 

the low-speed turns on automatically, it cannot be 

deactivated from the panel, however the high speed 

may be started.

          3 CIRCULATION PUMP MODES

If the spa is equipped with a circulation pump, it will 

be configured to work in one of the following  

three modes:

MODE 1:  

The circulation pump will operate 

continuously (24 hours) with the exception of turning 

Off for at least 30 minutes at a time when the 

water temperature reaches 3°F (1.5°C) above the 

set temperature (most likely to happen in very hot 

climates).

MODE 2:  

The circulation pump will stay on 

continuously, regardless of the water temperature.

MODE 3:  

A programmable circulation pump will 

come on when the control system is checking the 

water temperature (polling), during filter cycles, during 

freeze conditions, or when another pump is on.

Circulation pump modes are determined by  

the Manufacturer and cannot be changed  

in the field.

  HOW DOES YOUR CONTROL SYSTEM 

CHECK THE WATER TEMPERATURE?

The control system (A) activates a pump that 

circulates water from the spa tub through the water 

heater (B) shown below. The water heater contains 

two temperature sensors (C). When water flows 

around the sensors, the control system calculates 

the water temperature. This process is referred to 

as “polling” in this user guide. 

  HEATER PUMP

The heater pump is any pump dedicated to 

circulating water through the water heater. If your 

spa has a circulation pump, the circulation pump 

will serve as the heater pump. If your spa does 

not have a circulation pump, a two-speed pump 

will serve as the heater pump. If the heater pump 

is a two-speed pump, anytime it is activated 

automatically (for any reason, including to check 

the water temperature), it will activate at low speed. 

A

B

C

SPA BEHAVIOR

Summary of Contents for TP700

Page 1: ...TP700 PANEL User Guide Your Single Source Solution 42369 Rev A ...

Page 2: ...ter Group Your Single Source Solution THANK YOU for using Balboa Water Group spa controls TP700 PANEL BP CONTROL SYSTEM Software Version 7 0 and later Home Page www BalboaWaterGroup com TP700 Video Tutorials www BalboaWater com TP700 Quick Tips ...

Page 3: ... SPA DEVICES 14 SET FILTER CYCLE TIMES 16 RESTRICT OPERATIONS 17 INVERT DISPLAY 18 SPA BEHAVIOR 20 HEAT SETTINGS 26 FILL IT UP 28 SETTINGS 30 PANEL MESSAGES 30 GENERAL MESSAGES 30 HEATER RELATED MESSAGES 32 SENSOR RELATED MESSAGES 33 SYSTEM RELATED MESSAGES 34 REMINDER MESSAGES 36 MISCELLANEOUS 36 MESSAGE NOTES 38 DIAGNOSTICS 38 SYSTEM INFORMATION 39 FAULT LOG 40 GFCI TEST 42 WARNING Notes ...

Page 4: ...ion Arrow J Heat Status K Selection Box L Message May Appear Information Reminder Error Normal Error or Warning Error Spa will not function until fixed M Water Temperature Fahrenheit temperatures are displayed without decimal points For example 100 F is displayed as 100 Celsius temperatures are displayed with decimal points For example 37 5 C is displayed as 37 5 N Water Temperature Bar O Set Temp...

Page 5: ... Navigation arrow D corresponds to the RIGHT navigation button The left Navigation arrow M corresponds to the LEFT navigation button etc Back Button Use the Back button L to navigate back in the menus Use the navigation buttons to select the Back button The Selection box L indicates that the Back button is selected Press the SELECT navigation button On Off Switches In this example the Reminders se...

Page 6: ...dicates more menu items View Message Screen 1 Start from the Main screen A and press the LEFT navigation button to select the Message icon B 2 Pressing the SELECT navigation button to view the Message screen 3 The Message screen may have an Exit button or a Clear button Select the button on the screen and press the SELECT navigation button View Exit and Clear Buttons on page 31 for more informatio...

Page 7: ...te the dashes disappear and the water temperature is displayed B The dashes may reappear after the pump has not run for one hour CHANGE THE SET TEMPERATURE Main Screen A C E B D Heater On Note the Heater Status icon flashes during heater start up this is normal F There are two ways to run spa devices 1 Run spa devices by pressing any of these buttons G 2 Run spa devices from the Spa screen by foll...

Page 8: ...g the filter cycle 2 In Rest Mode heating only occurs during the filter cycle 3 Purges happen at the start of each filter cycle on most systems For example if your spa is set up for 24 hour circulation except for shutting Off when the water temperature is 3 F 1 5 C above the set temperature that shutoff does not occur during filter cycles Model AX10 Model AX20 Model AX40 Auxiliary Panels A B Keep ...

Page 9: ...proximately 5 seconds After 5 seconds the toggle switch will move to the right and turn blue G and a lock icon will appear E You have locked the Settings Follow the same steps to lock unlock the Settings and or Panel 5 Navigate back to the Main screen The lock icon on the Main screen H indicates that the Settings are locked Can Settings and Panel be locked simultaneously Yes The lock icon H appear...

Page 10: ...ut period If your spa does not have a circulation pump Pump 1 will run at low speed when the blower or any other pump is on If the spa is in Ready Mode view page 22 Pump 1 low may also activate for at least 1 minute every once in a while to detect the spa temperature polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from th...

Page 11: ...ode 2 REST MODE Rest Mode only heats the water during filter cycles If you do not use your spa for an extended period of time you may want to use Rest Mode 3 READY IN REST MODE This mode is a sub feature of Rest Mode When your spa is in Rest Mode and you press the JETS 1 button Rest Mode will automatically switch to Ready In Rest Mode for one hour During this hour the control system will attempt t...

Page 12: ...w the current Heat Mode on the Main screen The current Heat Mode is displayed here with an icon E In this example the current Heat Mode is Ready The following list shows which icons may appear on the Main screen HEAT SETTINGS TEMPERATURE RANGES E A View page 10 for information on navigating the Settings menu B C Main Screen Heat Mode Icons Ready Rest Ready in Rest D Follow these steps to view the ...

Page 13: ...llow these steps to view the current M8 setting and or turn it On Off 1 Navigate to Heat A 2 Press the SELECT navigation button to view the Heat screen B The current M8 will appear here C In this example the current M8 setting is Off 3 Press the SELECT navigation button to change the M8 setting from Off to On D M8 is turned On The change takes effect immediately No need to press a Save button Note...

Page 14: ...water temperature Follow these steps to prime any one speed pump including a circulation pump Press the button JETS 1 JETS 2 etc for that pump once to turn it On Run the pump for 2 minutes If priming is not complete after 2 minutes turn Off the pump and repeat the process Which pump is the heater pump When the spa has just entered Priming Mode press the LIGHT button B and see if any water flows If...

Page 15: ...n power to the spa Drain Mode Optional Some spas have a special feature that allows Pump 1 to be employed when draining the water When available this feature is a component of Hold CLEANUP CYCLE Optional When a pump or blower is turned On by a button press a Cleanup cycle begins 30 minutes after the pump or blower is turned Off or times out The pump and the ozone generator will run for 30 minutes ...

Page 16: ...in again after about 1 minute See Flow Related Checks below The water flow has failed Message Code M017 There is not enough water flow through the heater to carry the heat away from the heating element and the heater has been disabled See Water Flow Checklist on page 37 After the problem has been resolved reset the message The heater may be dry Message Code M028 Possible dry heater or not enough w...

Page 17: ...service organization Configuration error The spa will not Start Up Contact your dealer or service organization The GFCI test failed System Could Not Test the GFCI Message Code M036 North America Only May indicate an unsafe installation Contact your dealer or service organization A pump may be stuck On Message Code M034 Water may be overheated POWER DOWN THE SPA DO NOT ENTER THE WATER Contact your ...

Page 18: ...ay appear on a regular schedule i e every 30 days The GFCI or RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular...

Page 19: ...Selection box defaults to the Clear or Exit icon A on the Message screen Press the LEFT navigation button to move the Selection box to the Error Warning Reminder icon B and then press the SELECT navigation button to go to the System Information screen view page 38 37 TP700 USER GUIDE 42370 Rev A 36 Balboa Water Group Your Single Source Solution Control System No Communications Panel Cable Panel WA...

Page 20: ...ault Log is an actual fault For example message code MO19 is inserted into the fault log to identify each time the spa restarts A Each time a fault occurs it is assigned a unique number starting with number 1 The next fault is assigned number 2 and so on Up to 24 faults can be stored in memory In this example the fault number is 2 24 C This means it is the second fault in a list of 24 faults The f...

Page 21: ...systems that do not have the automatic GFCI test the manual GFCI test must be done FORCING A MANUAL GFCI TRIP TEST The installer can cause the GFCI Trip Test to occur at any time by activating Test A on the GFCI Test screen The GFCI should trip within several seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the ci...

Page 22: ...er differentiel avant d utiliser le bain Lire la notice technique Lorsque l appareillage est installe dans une fosse on doit assurer un drainage adequat Employer uniquement a l interieur d une cloture CSA Enclosure 3 Connecter uniquement a un circuit protege par un disjoncteur differentiel de Class A Afin d assurer une protection permanente contre le danger de shock electrique lors de l entretien ...

Page 23: ...ice is available M F 7 00AM to 6 00PM PT Corporate Office Balboa Water Group 3030 Airway Avenue Costa Mesa CA 92626 MEXICO OPERATIONS Balboa Water Group Aguila Azteca 6011 Baja Maq El Aquila Mexico 22221 EUROPEAN OPERATIONS Balboa Water Group HydroAir International ApS Roustvej 50 6800 Varde Denmark TP700 PANEL ...

Reviews: