Initial Start Up

Your spa enters 

Priming Mode

 for 4-5 minutes when 

energized to purge jets of air. During Priming Mode, 

Jets         

are displayed. Turn on all Jets to facilitate 

priming. Priming Mode can be manually exited 

anytime. Afterwards, the

 Main Screen 

is displayed. A 

minute later, current temperature appears and if 

needed, the heater begins. At this point, it is important  

to set the Time Of Day and Filter Cycles.

Basic Operation 

1. The Main Screen 

contains basic information and 

controls. Change the Set Temperature on the left of the 

screen. Messages may appear and be dismissed at the 

bottom of the screen. White text items proceed to 

additional controls. The menu screens time out after 30 

seconds. After 3-5 minutes the display goes into sleep 

mode. Touch anywhere to wake the screen up. 

Setting Temperature

:

 Select temperature display (eg: 

102*F) and press Up/Down to set. Press Back to save.

2. The Spa Screen

 controls pumps, lights, and invert. 

      

 

Jet Buttons

 turn pump on/off and shift between 

low/high-speeds. If left running, pumps turn off after a 

timeout period. If Pump 1 turns on automatically, it 

cannot be deactivated, but high speed can be activated.

       

Light Button

 turns lights on/off and proceeds 

through lighting options. 

      

 

Invert Button

 

reverses the orientation of the screen 

and allows easier control from inside the spa. 

3. The Scenes Screen

 programs jet & lighting patterns. 

With the spa in desired settings, hold your finger over a 

Scene selection for 5 seconds until “Scene Stored” 

appears on the bottom of the screen. The scene will be 

programed into the spa and can be accessed here. 

4. The Settings Screen

 controls additional features and 

options. When an item is selected, it will toggle 

between two settings. Menu items with a right arrow 

lead to another control level. 

Dual Temperature Ranges:

 This system incorporates 

two temperature ranges with independent set 

temperatures. When a range is chosen, the spa will heat 

to the temperature set in that range. 

High Range

 is for 

standard use and set between 80* F and 104* F. 

Low 

Range

 is for periods of low use and set between 50*F 

and 99*F. Freeze Protection is always active. 

Heat Modes:

 

Ready Mode: Pump 1 circulates water every 1/2 hour to 

maintain set temperature, heat as needed, and refresh 

temperature display. This is known as “polling”. 

Rest Mode:

 

 Spa heats only during programmed filter 

cycles. Polling does not occur, so the temperature 

display may not be current until the filtration pump has 

run for a minute or two. 

Ready-in-Rest Mode appears if the spa is in Rest Mode 

and Pump 1 is activated. When the heater pump comes 

on automatically (ex: for heating) you can switch 

between low and high speed but cannot turn the heater 

pump off. After 1 hour, system reverts to Rest Mode. 

Setting the Time:

 

determines filtration and other 

features. In Settings Screen, select 

Time-Of-Day

. Then 

select Hour, Minutes, and 12/24 Hour segments. Use 

Up and Down Buttons to change. 

Filtration:

 

It is important to set a filter pattern. We 

recommend two, 2-hour cycles programmed 12 hours 

apart at 7am/7pm (avoid hours between 10am-5pm). In 

Setting Screen, program start time and duration. End 

time is then calculated. Filter Cycle 2 is OFF by default 

and displayed as 

No

. When it is ON, 

Yes

 is displayed. 

Press 

Yes

 or 

No

 to toggle Filter Cycles ON or OFF.

Lock:

 

Spa control can be locked to prevent unwanted 

use. To lock, select “Settings” or “Panels” and press 

“Save.” 

Locking Settings

 prevents adjusting Set 

Temperature and programmed settings, but allows use 

of jets and display controls. (Filter Cycles, Invert, 

Information and Fault Log can be seen, but not edited.) 

Locking Panel

 prevents use of all controls, but 

maintains automatic functions. 

Unlocking:

 To unlock controls, select 

Settings (if it says “On”) or Panel (if 

it says “On”), then hold the middle of 

the screen for at least 5 seconds until 

“On” turns to “Off.” Follow the QR 

link* to the left for more info. 

*youtube.com/watch?v=emHP_Hu00x8

5. Exiting Screens

 

When you see both of these buttons, they 

always mean 

Save

 and 

Cancel

. If the screen 

times out due to no activity, it acts as 

Cancel. When you see only the 

Save

 button, 

it means Back or Exit and appears on 

editing screens before you have changed 

any value and on all other screens. 