Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and 

jets in the plumbing system before fi lling to allow as much air as pos-

sible to escape from the plumbing and the control system during the 

fi lling process. When your spa is fi rst actuated, it will go into Priming 

mode, indicated by “

PR 

” The Priming mode will last for less than 

5 minutes (press „Cool” or „Warm” to skip Priming Mode) and then the 

spa will begin to heat the spa and maintain the water temperature in 

the Standard mode. 

Buttons

 JETS

Press the “Jets”        button once to turn pump on or off , and to shift 

between low and high speeds if equipped. If left running, the pump 

will turn off  after a timeout period. The pump low speed timeout on 

some systems may be as long as 4 hours. On non-circ systems, the low 

speed of pump 1 runs when the blower or any other pump is on. It 

may also activate for at least 1 minute every 30 minutes to detect the 

spa temperature (polling) and then to heat to the set temperature if 

needed, depending upon mode. When the low speed turns on auto-

matically, it cannot be deactivated from the panel; however, the high 

speed may be started.

The last measured temperature is constantly displayed on the LCD 

screen.

Please note that the last measured water temperature only ap-

pears exactly when the pump has run at least for 1 minute.

To display the set temperature, press the Cool         or Warm         

button once. To change the set temperature, press the button a 

second time before the LCD stops fl ashing. Each press of the “Cool” or 

“Warm” button will continue to either lower or raise the set tempera-

ture. After three seconds, the LCD will stop fl ashing and display the

current spa temperature.

 LIGHT

Press the “Light”   button to turn the light on and off . If left on,

the light automatically turns off  after 4 hours.

MODE

Mode is changed by pressing the “Cool”        or “Warm”     

button, then pressing the “Light”       button.

Standard Mode is programmed to maintain the desired tempe-

rature. Note that the last measured spa temperature displayed 

is current only when the pump has been running for at least 2 

minutes. “

St

 

” will be displayed momentarily when you switch into 

Standard Mode.

Economy Mode heats the spa to the set temperature only during 

fi lter cycles. “

Ec

” will display solid when temperature is not current, 

and will alternate with temperature when temperature is current.

Sleep Mode heats the spa to within 20°F/10°C of the set tempera-

ture only during fi lter cycles. “

Sl 

” will display solid when tempe-

rature is not current, and will alternate with temperature when 

temperature is current.

Preset Filter Cycles

The fi rst fi lter cycle begins 6 minutes after the spa is energized.

The second fi lter cycle begins 12 hours later. Filter duration is

programmable for 2, 4, 6, 8 hours or for continuous fi ltration

(indicated by “

FC 

”). The default fi lter time is 2 hours.

To program, press “Cool”        or “Warm”         then “Jets” 

Press “Cool” or “Warm” to adjust. Press “Jets” to exit programming.

For more information, please, check the User Manual.

VL260 CONTROL 

COOL

WARM  –  SET TEMPERATURE