PanaFlow™ LC User’s Manual
47
Appendix A. Specifications and Model Configurations
Appendix A. Specifications and Model Configurations
A.1 Operation and Performance
Fluid Types
Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained
solids or gas bubbles. Maximum void fraction depends on transducer, interrogation carrier frequency, path length,
and pipe configuration.
Flow Measurement
Correlation transit time technique
Accuracy
•
±1%: >=2 in pipe; greater than 1 ft/s velocity
•
±2%: <=2 in pipe; greater than 1 ft/s velocity
Accuracy statement assumes measurement of a single phase homogenous liquid with a fully developed
symmetrical flow profile passing through the meter (typically 10 diameters upstream and 5 diameters downstream of
straight pipe run). Applications with piping arrangements (e.g. two out of plane elbow at upstream) that create an
asymmetrical flow profile may require extended piping straight runs and/ or flow conditioning for the meter to
perform to this specification.
Calibration
All meters are water calibrated and include a calibration certificate.
Repeatability
±0.15% of reading
Range (Bidirectional)
-82 to 82 ft/s (-25 to 25 m/s)
Rangeability (Overall)
50:1
Transducers supported
•
UTXDR 4 and 2 MHz
•
CF-LP 4 MHz
•
CRS 0.5, 1.0 and 2.0 MHz
•
CPT HT 0.5, 1.0 and 2.0 MHz
•
CET
•
CRR 0.5, 1.0, and 2.0 MHz
•
CAT 0.5, 1.0, and 2.0 MHz
•
CF-JR 4.0 MHz
Process Fluid Temperature Range
Local mount: -40°F to 185°F (-40°C to 85°C)
A.2 Electronics
Refer XMT1000 user manual for the specifications.
Summary of Contents for Panametrics PanaFlow LC
Page 1: ...panametrics com BH029C11 EN C PanaFlow LC User s Manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 64: ...Appendix D CE Mark Compliance 56 PanaFlow LC User s Manual no content intended for this page...
Page 66: ...Warranty 58 PanaFlow LZ User s Manual no content intended for this page...
Page 67: ......