PanaFlow™ LC User’s Manual
23
Chapter 2. Installation
2. Thread one end of transducer cables into 3 channel junction box as shown in
. (Cable locations in
are for reference only. Transducer cables can be placed in any orientation)
Figure 30: XMT1000, 3 Channel Junction Box
3. Thread CH1 UP transducer cable into upstream junction box of the transducer set you will use for channel one.
Repeat for CH1 DN and remaining channels.
4. Remove cover on transducer junction box and terminate BNC end of transducer cable to the BNC on the
transducer for each channel. Replace junction box covers.
5. Open cover to 6 channel junction box and make connections between transducer cable BNCs and trunk cable
BNCs. Verifying transducer cables have the same channel labels as the trunk cable wires. Replace junction box
cover.
6. Open the back lid of the XMT1000 meter to access the wiring connections of the meter
.
7. Connect the MCX ends of the 6-connector cable to the corresponding labeled MCX connector in the back of the
XMT1000 meter. UP1 must connect to UP1 and so on.