Chapter 2. Installation
22
PanaFlow™ LC User’s Manual
2.6 Wiring instructions
Please refer to the XMT1000 User Manual for wiring of:
•
Analog outputs
•
Digital outputs (totalizer, frequency, calibration)
•
Modbus or Service port
•
Hart or Foundation Field Ports (if applicable)
•
Additional analog input or output (if applicable)
•
Additional SIL analog output (If applicable)
•
Transducer (flying leads)
•
Line power
2.6.1
Three Channel Setup
The XMT1000 User manual details wiring for a one or two channel installation. However, for a three channel system,
please follow the instructions below.
Components of a three channel PanaFlow LC will be: a meter head, 6 conductor “trunk” cable, 3 channel junction box,
6 transducer cables and 3 sets of transducers and clamping fixtures. Mount meter head and junction box to a two
inch post using included hardware or another location following local electrical and building codes.
Install transducers as mentioned in
Section 2.4.3.3 "Installation of Transducer”
. Prepare to wire transducer cables.
Note:
US/ Canada installations will be required to provide conduit per their particular location. European
installations will include armored cable.
2.6.1.1
Transducer Wiring (ATEX installations)
1.
Thread MCX end of 6 conductor cable trunk into XMT1000 meter head and the BNC connector end of the cable
into the 3 channel Junction box as seen in
Figure 29: XMT1000 Trunk cable Placement
Summary of Contents for Panametrics PanaFlow LC
Page 1: ...panametrics com BH029C11 EN C PanaFlow LC User s Manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 64: ...Appendix D CE Mark Compliance 56 PanaFlow LC User s Manual no content intended for this page...
Page 66: ...Warranty 58 PanaFlow LZ User s Manual no content intended for this page...
Page 67: ......