Replacement Parts List 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical Items 

Baker Part Number 

Mag. Guage 

20773 

Electrical panel assembly 

338A505 

Gas Cylinder  

41041 

Ball socket for gas spring 

40902 

Inter-Chamber Door 

338A604 

Pass-Through Door Assembly 

338A306 

Work Chamber Viewscreen 
Assembly 

338A305 

Connector, Gloveport Sleeve 

39608 

Filter, HEPA, 18” x 35” x 3” 

351A103 

Filter, HEPA, 18” x 20” x 3” 

338A104 

Filter, HEPA, 11.5” x 13” x 6” 

39797 

Filter, HEPA, 9” x 13” x 6” 

40817 

Replacement Filters kit for 
complete cabinet 

351G000 

Latch, Inter-Chamber Door 

40114 

Latch, Pass-Through Door 

40114 

Latch, Work Chamber Viewscreen 

40881 

Nitrile Glove, SM/MED/L/EXL 

40699 / 40700 / 40701 / 40703 

Electrical Items 

Baker Part Number 

Fluorescent Lamp – Work 
Chamber 

41387 

Lamp Holder – Plunger End 

41438 

Lamp Holder – Fixed End 

41439 

Ballast 

41385 

Fluorescent Lamp – Pass through 

38682 

Lamp Holder – Pass through 

35072 

Rocker Switch - Lights 

15826 

Rocker Switch - Aux 

15826 

Rocker Switch – Duplex outlets 

15826 

Terminal Block 

39195 

351D700 Rev G 

 

 

 

 

14 

Summary of Contents for ChemoSHIELD CS500

Page 1: ...o bakerco com bakerco com OPERATOR S MANUAL Negative Pressure Isolator MODEL CS500 Revision Date Description H 5 19 15 UPDATED BRANDING This manual includes information for installation operation main...

Page 2: ...laboratory personnel In addition to the high quality you expect from all Baker equipment this model has been ergonomically designed to provide the lab user with many exciting design features The ergo...

Page 3: ...3 Easy filter access 4 Telescoping stand 4 Mechanical interlock between pass through door inter chamber door 4 Pressure monitoring of chambers 4 Airflow monitor AFM 4 Auxiliary switch Optional 4 Elec...

Page 4: ...HEPA FILTERS 12 REMINDERS 12 APPENDIX 13 REPLACEMENT PARTS LIST 14 AIRFLOW MONITOR OPERATION CALIBRATION 15 WARRANTY 16 WARNING The agents used and or work performed in this cabinet may be hazardous t...

Page 5: ...ection while the sealed work chamber and HEPA filtered airflow provides product protection Fig 1 Airflow Inside Cabinet Negative Pressure The pass through chamber allows operators to introduce or remo...

Page 6: ...ny features that sets the ChemoSHIELD unit apart from other cabinets is the interaction of its pressure areas The whole cabinet is under negative pressure when operating The pass through chamber opera...

Page 7: ...protected by a smooth white baked enamel finish Tested HEPA filters The filters in the ChemoSHIELD are scan tested HEPA filters They are 99 99 effective on particles of 0 3 micron in size Each filter...

Page 8: ...are comparing chamber pressure to the room pressure Airflow monitor AFM The AFM is an audible and visual alarm system consisting of solid state flow measuring and alarm circuitry in a small enclosure...

Page 9: ...at the site of installation The cabinet is to be powered by a 115 V AC 15A 60 Hertz Single Phase dedicated circuit This circuit should be protected by a 15A circuit breaker or fuse Typical Current for...

Page 10: ...ndoor use Altitudes up to 2000 meters Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Main supply voltage 105 to 125Volts AC Transient over...

Page 11: ...Explosive or flammable substances should never be used in this cabinet Location Within the Laboratory Position the ChemoSHIELD so the pass through chamber end is 15 away from any wall or obstruction...

Page 12: ...guidelines Reference the cabinet factory test report for information on the test criteria used NOTE This test should be performed before the cabinet is connected to the building exhaust system See Fig...

Page 13: ...ch will illuminate when the fluorescent lights are turned on 2 Auxiliary AUX Switch Optional This switch is available for wiring to a building exhaust system fan blower so that it can be turned on off...

Page 14: ...been open and closed to allow the chamber and tunnel to purge with HEPA filtered air Unloading and Wipe down 1 Close the inter chamber door before opening the pass through door when unloading material...

Page 15: ...m being killed Standard disinfectants include Hypochloride chlorine bleach Iodophor Detergent Ethanol Phenol and Alcohol IMPORTANT Disinfection and cleaning should always be followed by rinsing in ste...

Page 16: ...Company for more information It must be pointed out that the HEPA filter is not intended to filter gasses or vapors nor are they 100 efficient on particulates The room and cabinet particulate levels...

Page 17: ...Appendix 351D700 Rev G 13...

Page 18: ...13 x 6 39797 Filter HEPA 9 x 13 x 6 40817 Replacement Filters kit for complete cabinet 351G000 Latch Inter Chamber Door 40114 Latch Pass Through Door 40114 Latch Work Chamber Viewscreen 40881 Nitrile...

Page 19: ...n normal airflow is resumed the BLOWER relay will change states and will have a slower single audible alarm The red LED will be latched ON solid until reset with the Alarm Reset button No Probe Red an...

Page 20: ...nc will F O B Sanford Maine furnish without charge repairs to or replacement parts or equipment which proved defective in material or workmanship No claim may be made for any incidental or consequenti...

Reviews: