26 | Baker Hughes.
© 2021 Baker Hughes Company. All rights reserved.
Required Tools
The following tools are needed to complete the rotary valve installation:
To mount the SVI3:
1. Attach the SVI3 rotary mounting bracket to the valve actuator with two 5/16 - 18 UNC
flat-head cap screws and tighten using 3/16" Hex Key as shown in Figure 8.
Figure 8 Camflex ATO and ATC Mounting
• 3/16" Hex Key with tee handle
• 5/32", 1/2" Hex Key
• 3 mm, 4 mm, 5 mm Hex Key
• 7/16" Wrench
Four 5⁄16 - 18 UNC
flat-head cap
screws
Air-to-close (ATC)
Set magnet when
actuator is energized
Magnet Axis
Magnet Axis
Long end of bracket to left(preferred)
Air-to-Open
Long end of bracket to left(preferred)