![Baker Hughes Masoneilan SVi 1000 Quick Start Manual Download Page 60](http://html1.mh-extra.com/html/baker-hughes/masoneilan-svi-1000/masoneilan-svi-1000_quick-start-manual_3524543060.webp)
60 |
© 2021 Baker Hughes Company. All rights reserved.
Appendix D. Specifications, Spare Parts and
References
Physical and Operational Specifications
This section provides the physical and operational specifications for the SVi1000. Specifications
are subject to change without notice.
Table 7: Environmental Specifications
Parameter
Storage & Transport (Packaged)
Operating Temperature Limits
-40°F to 185°F (-40°C to 85°C)
Storage Temperature Limits
-58°F to 200°F (-50°C to 93°C)
Temperature Effect
< 0.005% / °F typical; -40°F to 180°F
(< 0.01% / °C typical; -40°C to 82°C)
Supply Pressure Effect
0.05% per psi (.73% per bar)
Operating Relative Humidity
5 to 100% non-condensing
Storage Relative Humidity
0 to 100% non-condensing
Humidity Effect
Less than 0.2% after 2 days at 104 °F (40 °C),
95% Relative Humidity.
Electromagnetic Compati-
bility Electrostatic
o
IEC 61514 Industrial-Process Control
systems - methods of evaluating the
performance of intelligent valve positioners
with pneumatic outputs.
o
IEC 61326 Electrical equipment for
measurement, control and laboratory use -
EMC requirements.
Fast Transient Burst
No effect at 2 kV (Coupling clamp EN61000-4-4 or
IEC1000-4-4).
Vibration Influence
Measured at SVi1000 Hous-
ing
o
4 mm at 5 - 15 Hz - Negligible
o
2 G at 15 - 150 Hz Less than 2 % of span
o
1 G at 150 - 2000 Hz - Less than 2% of span
Housing
Tropicalized with positive pressure
Magnetic Field Influence
Negligible at 100 A/m 50/60 Hz (EN61000-4-8)
CE MARK
The SVi1000 conforms to the requirements of the