Copyright 2020 Baker Hughes Company. All rights reserved.
Page 236 of 277
Table 62: Trigger Types (full list) (cont'd.)
Action (User Level)
Description
Internal Trigger
(Advanced)
Only use advanced trigger types under direction
from engineering!
External Trigger
(Advanced)
Only use advanced trigger types under direction
from engineering!
Is SET, Cleared on
(Advanced)
Activates when Source 1 is SET. Clears when
Source 2 is SET.
Only use advanced trigger types under direction
from engineering!
Is SET or Counting
(Advanced)
Activates if Source 1 is SET or is counting down
for a restart.
Only use advanced trigger types under direction
from engineering!
10.9
Trigger Actions (Full List)
“Basic” Trigger Actions are appropriate for at least 90% of the triggers that will need to be field configured.
These actions are automatically selected when the user executes the
“Add a Trigger” function from the
Channel Info screen.
“Standard” Trigger Actions may be necessary in a small number of situations – like
implementing tank level control from an ESP template.
“Advanced” Trigger Actions will rarely be used by
the field engineer.
Table 63: Trigger Actions (full list)
Action (User Level)
Color Scheme (background)
Description
Logic Only
(Basic)
Brown
The trigger has no effect on the
motor control state machine and
is not logged. The Logic Only
trigger can be used as an input to
other (derived) triggers.
Log Only
(Basic)
Dark Purple
The trigger has no effect on the
motor control state machine but is
logged in the Even Log.
Summary of Contents for Apollo 3