Copyright 2020 Baker Hughes Company. All rights reserved.
Page 166 of 277
Mtr Spd PID
‘P” and Mtr Spd PID “I” are the PID Loop proportional and integral constants. Adjust these
to tune the PID.
5.15
Add a 2nd IO Board
The Apollo Well Control System can support a second Apollo I/O board. A second I/O board system may
be needed in SPS Systems with lots of sensors.
Set Switch S2 position 1 to ON, position 2 to OFF on the second Apollo I/O board.
To execute the wizard, from the Home Screen select:
Settings -> Menu -> Other Initial Setup -> Right Arrow -> Right Arrow -> Configuration Wizards -> 2
nd
IO
Board
Follow the on-screen directions.
The 2
nd
IO Board wizard requires no information.
When the wizard is complete, the analog and digital I/O from the added Apollo I/O board will appear in the
Analogs and Digital IO Data Display screens. Analog options are denoted E2 Analog Option 1-8 and
digitals are denoted E2 Dig Opt 1-12.
These new channels can be added to a Data Display screen, if desired.
5.16
Edit a Screen
Apollo Data Display screens can be customized as needed by the application.
illustrates the process.
1. Log on as level 2 or level 3.
2. Navigate to the screen to be customized. In this example,
we’ll customize the Home Screen.
3. Use the Down Arrow button to highlight the screen name.
Summary of Contents for Apollo 3
Page 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Page 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Page 267: ......
Page 276: ......
Page 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...