Table 30: Download Limits #2 Common Installations
Parameter
Default
Description
Discharge High
Not In Use
The discharge pressure high
trigger is a Stop->Fault trigger
used to protect the system. Select
Discharge High to set the limit.
Set the Trip Delay and Restart
parameters as desired.
Discharge Low
Not In Use
The discharge pressure low
trigger is a Stop->Fault trigger
used to protect the system. Select
Discharge Low to set the limit.
Set the Trip Delay and Restart
parameters as desired.
DeltaPressHigh
Not In Use
The delta pressure high trigger
is a Stop->Fault trigger used
to protect the system. Delta
pressure is the differential
pressure across the pump
(Discharge Pressure
– Intake
Pressure). Select DeltaPressHigh
to set the limit. Set the Trip Delay
and Restart parameters as
desired.
DeltaPress Low
Not In Use
The delta pressure low trigger is a
Stop->Fault trigger used to protect
the system. Delta pressure is
the differential pressure across
the pump (Discharge Pressure
– Intake Pressure). Select
DeltaPress Low to set the limit.
Set the Trip Delay and Restart
parameters as desired.
Select any trigger you wish to adjust and make the necessary changes. Press the Save function button.
Acknowledge the confirmation screen by pressing the Yes function button. Press the Exit function button
to return the Downhole Limits menu.
When all the necessary changes have been made, press the Exit function button to return to the Main Menu.