LOOP INTERFACE MODULE CONFIGURATION (INLIM03)

INTRODUCTION

B - 2

  

I-E96-408A

®

52

34

0 0 1 1 0 1 0 0

Messages  stored  in  BIM  receive  buffer.

53

35

0 0 1 1 0 1 0 1

Interrupt  Requests  (IRQs)  sent  by  BIM.

54

36

0 0 1 1 0 1 1 0

High  Priority  (HP)  messages  transmitted.

55

37

0 0 1 1 0 1 1 1

High  Priority  messages  received.

56

38

0 0 1 1 1 0 0 0

Commands  issued  by  the  BIM.

57

39

0 0 1 1 1 0 0 1

Missed  BIM  transmit  requests.

58

3A

0 0 1 1 1 0 1 0

Spurious  Non-Maskable  Interrupts  (NMI)  caused 
by “address present.”

59

3B

0 0 1 1 1 0 1 1

HEY  (request  for  an  interrupt;  generated  by       
BIM) message sent.

60

3C

0 0 1 1 1 1 0 0

Messages  discarded  when  the  destination  is 
off-line.

61

3D

0 0 1 1 1 1 0 1

HEY  time  expirations.

62

3E

0 0 1 1 1 1 1 0

Passes  through  the  IDLE  level  (2  bytes  wide).

Table B-2.  LIM Error Counter Addresses (S1)

Counter

Address

Hex

Address

Switch Positions

(Binary  Address)

1 2 3 4 5 6 7 8

Description

64

40

0 1 0 0 0 0 0 0

Composite  error  count  developed  every  hand-
shake period - the summation of all other error 
counters.

65

41

0 1 0 0 0 0 0 1

Unresolved  NMI  interrupts.

66

42

0 1 0 0 0 0 1 0

Unresolved  IRQ  interrupts.

67

43

0 1 0 0 0 0 1 1

Unresolved  timer  interrupts.

68

44

0 1 0 0 0 1 0 0

Queue  overflow  message  losses.

69

45

0 1 0 0 0 1 0 1

Checksum  failures.

70

46

0 1 0 0 0 1 1 0

Unresolved  BIM  IRQs.

71

47

0 1 0 0 0 1 1 1

Sequence  errors.

72

48

0 1 0 0 1 0 0 0

Header  CRC/OVRN errors.

73

49

0 1 0 0 1 0 0 1

Data CRC/OVRN errors.

74

4A

0 1 0 0 1 0 1 0

Messages  developing  data  CRC errors en route 
to destination.

75

4B

0 1 0 0 1 0 1 1

Transmission  failures.

76

4C

0 1 0 0 1 1 0 0

Watchdog  timer  expirations.

77

4D

0 1 0 0 1 1 0 1

Data  length  errors.

78

4E

0 1 0 0 1 1 1 0

Loop  -  1  Receive  (RCV)  failure.

79

4F

0 1 0 0 1 1 1 1

Loop  -  2  Receive  failures.

80

50

0 1 0 1 0 0 0 0

Loop  -  1  Transmit  (TX)  failure.

81

51

0 1 0 1 0 0 0 1

Loop  -  2  Transmit  failures.

Table B-1.  LIM Event Counter Addresses (S1) 

(continued)

Counter

Address

Hex

Address

Switch Positions

(Binary  Address)

1 2 3 4 5 6 7 8

Description

Summary of Contents for Infi 90 NICL01

Page 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 408 Communication Termination Module NICL01...

Page 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Page 3: ...erface Module INLIM03 The NICL01 is designed to connect to communica tion loops of either twinaxial or coaxial cable This manual explains how to install and use the NICL01 It explains how to set the j...

Page 4: ...nal 5 1 Original A 1 through A 4 Original B 1 through B 3 Original Index 1 Original When an update is received insert the latest changed pages and dispose of the super seded pages NOTE On an update pa...

Page 5: ...h energized parts is avoided when servicing Special Handling This module uses Electrostatic Sensitive Devices ESD SPECIFIC CAUTIONS We strongly recommend that you turn cabinet power off before doing a...

Page 6: ...ions de Manutention Ce module contient des composantes sensibles aux decharges electro statiques ATTENTIONS D ORDRE SP CIFIQUE Il est fortement recommande de debrancher l alimentation elec trique du c...

Page 7: ...he Jumpers 2 3 INSTALLING THE TERMINATION MODULE 2 4 Installing the Termination Module Cables 2 4 Mounting the Termination Module 2 4 Communication Cable Installation 2 6 POWER WIRING 2 7 SECTION 3 MA...

Page 8: ...ters A 3 A 5 Error Counters A 4 B 1 LIM Event Counter Addresses S1 B 1 B 2 LIM Error Counter Addresses S1 B 2 B 3 PCU Address Settings S2 B 3 List of Figures No Title Page 1 1 The NICL01 within a PCU...

Page 9: ...ion until you read and under stand this instruction HARDWARE DESCRIPTION The ICL mounts in a Termination Mounting Unit NTMU01 02 inside the INFI 90 cabinet It is a printed circuit board that consists...

Page 10: ...ce of dipswitch and jumper settings for those modules HOW TO USE THIS MANUAL Read this manual before installing the ICL Do the installation steps in order Do not operate the ICL until you complete all...

Page 11: ...C non PVC NKLS02 NKLS12 Termination Mounting Unit rear mount front mount NTMU01 NTMU02 Term Definition Coaxial cable A special type of communications cable that permits the transmission of data at hig...

Page 12: ...nting unit NTMU01 02 Cooling Requirements No cooling necessary when used in Bailey cabinets and operated within stated environmental limits Operating Temperature 0o to 70oC 32o to 158oF Relative Humid...

Page 13: ...ystem Save the bag for future use 2 Ground Bags Before Opening Before opening a bag con taining an assembly with CMOS devices touch it to the equip ment housing or a ground to equalize charges 3 Avoid...

Page 14: ...LLATION Before you mount the ICL in the termination mounting unit check the fuse and jumpers Jumper settings configure the ter mination module to match the impedance of the communica tion cable These...

Page 15: ...t for LIS regard less of whether an LIS or LIM is used and J13 J18 are set for the cable type used Table 2 1 shows the jumper settings for revision C communication termination modules Table 2 2 shows...

Page 16: ...card edge sits within the card edge connector Refer to the product instructions for the INLIM03 or INNIS01 for more information about the installation or removal of those modules 2 Install the other e...

Page 17: ...Connectsindividual drops on the com munication loop Must connect to an NKTL01 on each end 2000 6562 INFI NET at 10 Mbaud 4000 13120 INFI NET at 2 Mbaud 2000 6562 Plant Loop NKPL03 PVC NKPL04 non PVC T...

Page 18: ...d on the circuit board and are shown in Figure 2 1 2 If using twinaxial cable connect the cable to the termina tion module at the terminal blocks TB2 and TB3 or TB4 and TB5 The terminal assignments ap...

Page 19: ...is ready for operation if 1 The fuse is installed 2 The jumpers are installed for the type of communication cable being used 3 The circuit board is mounted in the termination mounting unit 4 All requ...

Page 20: ...ualified personnel should perform maintenance MAINTENANCE SCHEDULE Table 3 1 is the maintenance schedule These tasks are to be performed at the specified intervals Table 3 1 Maintenance Schedule Task...

Page 21: ...o remove it 3 Remove the termination module from the termination mounting unit TMU 4 Remove the blown fuse from its holder F1 5 Replace the blown fuse with a 1 0 amp 250 volt fuse 6 Return the termina...

Page 22: ...to their terminal assignments as you remove them 4 Remove the faulty termination module 5 Align the circuit board of the replacement TM with the guide rails of its assigned slot within the termination...

Page 23: ...serial numbers if applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part When you order standard parts from Bailey Controls use part numbers and desc...

Page 24: ...ble A 1 shows how to set the NIS node address and ring number using dipswitches SW1 and SW2 Table A 2 lists the loop mode dipswitch settings SW3 Table A 3 shows examples of slave address settings SW4...

Page 25: ...OM Checksum Disabled 3 1 Test mode no timeout for handshake failure 0 Normal operating mode 41 0 Normal operating mode 1 Busy NAK all Loop Messages 51 0 LED display as defined by SW4 1 Will toggle on...

Page 26: ...umber of NIS poll messages acknowledged ACK by this node 0 1 1 1 1 0F Number of NIS poll messages busy not acknowledged BSY NAK by this node 1 0 0 0 0 10 Number of messages transmitted total loop traf...

Page 27: ...0 0 1 01 Number of channel 1 receive errors 0 0 0 1 0 02 Number of channel 2 receive errors 0 0 0 1 1 03 Number of transmitter errors 0 0 1 0 0 04 Number of messages lost to receive queue overflow 0...

Page 28: ...ist the event counter and error counter addresses for dipswitch S1 Table B 3 lists PCU addresses set by dipswitch S2 Refer to the INLIM03 instruc tion for more detailed installation and configuration...

Page 29: ...tion 64 40 0 1 0 0 0 0 0 0 Composite error count developed every hand shake period the summation of all other error counters 65 41 0 1 0 0 0 0 0 1 Unresolved NMI interrupts 66 42 0 1 0 0 0 0 1 0 Unres...

Page 30: ...0 1 0 1 1 12 0 0 0 0 1 1 0 0 44 0 0 1 0 1 1 0 0 13 0 0 0 0 1 1 0 1 45 0 0 1 0 1 1 0 1 14 0 0 0 0 1 1 1 0 46 0 0 1 0 1 1 1 0 15 0 0 0 0 1 1 1 1 47 0 0 1 0 1 1 1 1 16 0 0 0 1 0 0 0 0 48 0 0 1 1 0 0 0 0...

Page 31: ...1 INNIS01 A 1 Installation Communication cable 2 6 Fuse 2 3 Jumper 2 3 Mounting 2 4 Power wiring 2 7 Termination cable 2 4 Intended user 1 1 M Maintenance 3 1 Mounting 2 4 N Nomenclature 1 3 O Orderin...

Page 32: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Reviews: