15
15
Electrical
Connecting Power Supply
For three phase, connect the three power wires to terminals
R, S,
&
T.
Connect the ground
wire (typically green) to the “
E
” (Safety Ground) terminal.
Check for correct rotation of motor and pump.
Reset both “E”-STOP buttons. With power connected and disconnect switch turned “
ON
”, the
power light will be lit. Turn the cutting mode selector switch to (
SIN
). Press the green pump
start button and briefly step on the footswitch. The shear blade should come down. If not,
disconnect power to the machine, and switch the
R
&
T
wires.
DO NOT
move the ground
wire
E
.
Improper rotation can severely damage the hydraulic pump.
WARNING:
Baileigh Industrial is not responsible for any damage
caused by wiring up to an alternative 3-phase power source other than direct 3-
phase. If you are using an alternate power source, consult a certified electrician or
contact Baileigh Industrial prior to energizing the machine.
CAUTION:
HAVE ELECTRICAL UTILITIES CONNECTED TO MACHINE
BY A CERTIFIED ELECTRICIAN!
Check if the available power supply is the same as listed on the machine
nameplate.
WARNING:
Make sure the grounding wire (green) is properly
connected to avoid electric shock. DO NOT switch the position of the green
grounding wire if any electrical plug wires are switched during hookup.
Summary of Contents for SH-8008HD
Page 19: ...16 16 GETTING TO KNOW YOUR MACHINE I D E H J K A C O O P...
Page 47: ...44 44 ELECTRICAL ENCLOSURE BACK PANEL...
Page 57: ...54 54 NOTES...
Page 58: ...55 55 NOTES...
Page 59: ...56 56 NOTES...