25
25
Hydraulic System Bleeding
1. Verify that the hydraulic hose (29) is
connected to the block (27).
2. Verify that the air source supply pressure is
110~120PSI. The air motor requires this
pressure for working.
3. Open air valve (32) on top of pump reservoir.
4. Release the pump retract valve (35) and operate the hand
pump fast one minute, then operate the air motor half
minute for bleeding air out from hydraulic system.