![Baileigh Industrial PT-105HD-W Operator'S Manual Download Page 40](http://html1.mh-extra.com/html/baileigh-industrial/pt-105hd-w/pt-105hd-w_operators-manual_3454606040.webp)
37
37
•
Arc Set Step Value: From the cutting interface (main screen), Increase or decrease the Set
Arc Voltage value with each press of either F7 or F6. The range of value is 0.10-10.00. Unit:
V.
•
Fast IHS Time: The lifter motor runs time in full speed when IHS (initial height sensing). Then
the lifter motor runs the half speed until the torch contact the steel plate. Unit: s. Note: Fast
IHS Time cannot be more than Position Check Time. Fast IHS Time range of the value is 5.00-
100.00. Unit: V. Default 6.
•
Flame Updown Speed: Not used.
•
Plasma Updown Speed: Speed at which the torch lifts and lowers when reacting to a torch
height correction command. The normal range is set as 100.00%, the full range is 0.00-100.00.
Unit: %.
System Parameters
The system parameters are related with the precision of the transmission shaft of the machine.
Horizontal Axis Pulse
500.000
pulse/mm
Vertical Axis Pulse
500.000
pulse/mm
Max cutting speed
10000.000
mm/min
Max G00 speed
10000.000
mm/min
Max Manual speed
10000.000
mm/min
Small arc limit
2500.000
mm/min
Speed below Radius
10.00
mm
Flame adjust time
0.40
s
Plasma adjust time
0.30
s
Emergency stop time
0.08
s
Start speed
250.000
mm
Max +X
100000.000
mm
Max +Y
100000.000
mm
Min -X
-100000.000
mm
Min -Y
-100000.000
mm
F1
Common
F2
Flame
F3
Plasma
F5
System
F6
Import
F7
Export
F8
Save
•
Horizontal Axis Pulse: The number of pulse that the system needs to generate when the
machine move1mm towards X axis, maintaining 3 digits at most after decimal point.
•
Vertical Axis Pulse: The number of pulse that the system needs to generate when the machine
moves 1mm towards Y axis, maintaining 3 digits at most after decimal point.