54
54
LUBRICATION
Add a few drops of medium weight oil to the
six oil cups (A, Fig 25) weekly.
Lubricate the two table elevation screws (B,
Fig 26) as needed. Raise the table and remove
the two screws holding the top of the
accordion cover (C, Fig 26) in place. Pull the
cover down and lightly grease the elevating
screws, see Figure 26.
Use an oiled cloth to wipe the ways (D, Fig
26) weekly.
Lubricate the chain system with an oiled cloth
as needed.
The gear box oil should be changed once a year.
Remove the drain plug (E, Fig 27) to drain the
oil. Refill the gear box with 60-90 weight gear oil
through the fill hole (F, Fig 27) until the sight
glass reads full. The sight glass (G, Fig 27)
should be checked periodically and oil added as
necessary.