35
35
3. Enter the password. (2201)
4. Use
to scroll through the parameters.
5. Press
to lock or unlock.
On = unlock
Off = lock
6. Press
to confirm or press
to clear.
CONTROLLER TROUBLESHOOTING
Display
“Change RST” message appears when the Controller detects a motion in the wrong direction.
For example, the Controller switches the outputs to move upward but the table starts moving in
the reverse direction. Usually this is caused by the wrong wiring of the three phase motor.
1. Press
to clear.
2. Check the wiring and change if necessary.
Display
Possible cause:
a. no sensor
b. 9-pin connector is loose
c. wire broken
d. the gap between sensor and tape is too large