Bai cells EG7035 User Manual Download Page 12

 

 

Table 2-5 Environment Specification 

Feature 

Capability 

Operating Temperature 

-40

  ~ 55

 

Storage Temperature 

-40

  ~ 70

 

Operating Humidity 

5% ~ 95% 

Drop 

0.8m 

Protected Level 

IP67 

 

 

Regulatory Compliance 

2.6

 

FCC Compliance 

This device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference 
that may cause undesired operation. 

 

Any Changes or modifications not expressly approved by the party responsible 
for compliance could void the user's authority to operate the equipment. 

 

This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following 
measures: 

 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Summary of Contents for EG7035

Page 1: ...All rights reserved BaiCells Technologies Co Ltd BaiCells EG7035 User Manual V1 0...

Page 2: ...s without the prior written consent of BaiCells Disclaimer This specification is preliminary and is subject to change at any time without notice BaiCells assumes no responsibility for any errors conta...

Page 3: ...2 SW Specification 4 2 3 Device Management 5 2 4 Environment Specification 5 2 5 Regulatory Compliance 6 2 6 3 Product Installation 8 1 1 Installation Steps 8 4 CPE Configuration 9 Log in 9 4 1 Basic...

Page 4: ...on 14 A 2 Fails to Login to the web management page 14 A 3 The CPE fails to search for the wireless network 14 A 4 The power adapter of the CPE is overheated 14 A 5 The parameters are restored to defa...

Page 5: ...f EG7035 3 Figure 3 1 Install the Sample 8 Figure 3 2 Connection Diagram 8 Figure 4 1 Login Page 9 Figure 4 2 Setup Network Mod 10 Figure 4 3 LTE Setting 10 Figure 4 4 Setup Connect Method 11 Figure 4...

Page 6: ...EG7035 Appearance Index 2 Table 1 3 Description of EG7035 Interface and Button 3 Table 1 4 LED Indicators 3 Table 2 1 Basic Specification 4 Table 2 2 RF Specification 4 Table 2 3 SW Specification 4 T...

Page 7: ...ss access performance and comprehensive routing capabilities which have the abilities to bring the end users WBB services Features 1 2 EG7035 is designed according to the simplicity principle which ca...

Page 8: ...1 1 EG7035 Product Description Product Description EG7035 3 65G LTE Customer Premise Equipment Appearance 1 4 The appearance of EG7035 is shown in Figure 1 1 and is described in Table 1 2 Figure 1 1 E...

Page 9: ...1 4 LED Indicators LED Name Description Color LED Behavior Status Indicator PWR Power Indicator Green OFF No Power Supply Steady On Power On LTE Signal 3 LTEs Indicate connection state and signal str...

Page 10: ...2FF USIM None Restore Button Tact Button Long press over 10s to restore the factory settings Power Supply Input Universal range 100 240V AC Output 12V 1A None RF Specification 2 2 Table 2 2 RF Specifi...

Page 11: ...PnP Statistics LAN Link Status Transmit Receive traffic Running Time Device Management 2 4 Table 2 4 Device Management Item Description Maintenance Date Time setting Reset Restore factory settings Res...

Page 12: ...ted and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a r...

Page 13: ...ccept any interference including inter ference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux ap pareils radio exempts de...

Page 14: ...in Figure 3 1 2 Open the waterproof cover and according to the instructions on the SIM card 3 Connected to the adapter Pay attention to the adapter interface identify Figure 3 1 Install the Sample 4 M...

Page 15: ...3 Enter the user name and password click Login button After password authentication you can log on to the web management page The default user name password admin admin In order to more secure your d...

Page 16: ...following steps 1 Choose Network Setting LTE Setting 2 In the LTE Setting area you can configure the LTE network 3 In the LTE Setting area you can also view the network information such as frequency D...

Page 17: ...otherwise you should choose Manual 4 Click Submit Figure 4 4 Setup Connect Method Manual Connect Network 4 2 4 To manual connect the network perform the following steps 1 Choose Network Setting LTE S...

Page 18: ...3 You can choose full Band PCI Lock or a band the CPE supported Figure 4 5 Setup Scan Mode Setting Frequency Earfcn 4 2 6 To set the frequency perform the following steps 1 Choose Network Setting LTE...

Page 19: ...nt 3 In the APN Management area you can set the APN 4 Choose an APN number which you want to set 5 In the APN Setting area you can set the APN parameters such as enable or disable the APN APN name use...

Page 20: ...tructions such as concrete or wooden walls Check that the CPE is placed far away from household electrical appliances that generate strong electromagnetic field such as microwave ovens refrigerators a...

Page 21: ...15 Product List Appendix B Index Content Picture Amount 1 EG7035 CPE 1 2 12V 1A adapter 1 3 PoE Combiner 1 4 Mounting bracket 1 5 User Manual n a 1...

Page 22: ...BaiCells EG7035 Bracket Installation Guide V1 0 All rights reserved BaiCells Technologies Co Ltd...

Page 23: ...bracket and screw on do not tighten the screws 2 4 Install ground wire and lock the screw Tighten four screws using allen hexagon wrench Screw on four bacaket srews Put U shape screw on bracket of loc...

Page 24: ...Install on Pole Install on Pole 1 2 3 4 Loop U shape screw on pole and put on pole bracket Tighten U shape screw nut using wrench Tighten four screws Adjust CPE to a suitble position...

Reviews: