10. Technical Data
Housing:
Wall-mounted housing (DIN 43861-2)
Degree of protection:
IP52
Dimensions:
W = 105 mm,
H = 179 mm
D = 72 mm
Protection class:
1
Supply voltage:
80VAC to 270VAC or 60VDC to 375VDC
Power consumption:
About 4 VA
(depends upon supply voltage, kind of interface
module and operating status of transmission unit)
Interfaces:
Plug-in modules; available are:
- RS232 (supports signals RxD, TxD, RTS, CTS, GND, DTR,
DCD/DSR)
- CS (20mA current loop) active or passive
- RS485 (2 or 4 wires)
- M-Bus active: can supply 20 devices max.
Display:
LED’s for signals: operation, Hook, Rst, DCD, TxD and RxD.
Transmission rate remote
modem to UniMod:
300
– 33600 bit/sec (V.21 / V.22 / V.22bis / V.32 / V.32bis / V.34),
tone or pulse dialling
Transmission rate UniMod
to connected device:
300 to 19200 (115200) Baud, automatic baud rate detection
Data format:
7E1, 8N1, 8E1, ...
Data compression:
V.42bis / MNP5
Error correction:
V.42 / MNP4
Password:
Possible
Remote access:
Possible (with restriction)
Data Transmit Control:
Possible
Reset function:
Possible: every 3, 6, 12 or 24 hours
License:
EU-License CETECOM CE0682, reg. no. D800739K/CTR21
Extent of delivery:
- UniMod 01/I including interface module as ordered
- Standard cable TAE (length of cable about 3m)
- Operation manual
Accessories:
- Adapter for parametering with USB port (Order No.: #12823)
- Additional interface modules
- Suspension eye (Order No.: #9141)
- Software UniModSet