Warning and status messages
Page 16
LMS_FMS Compact_BA_02_0163
November 2016
10.
WARNING AND STATUS MESSAGES
The requested quantity has been higher than specified quantity in the
Menu Max.Dispense - Page 11
Dispense has been stopped with "Pulse Time Out".
No pulse are arriving from the meter, the Inactive Timeout has been exceeded.
See also page 9 - Inactive Timeout
The minimum tank level has been reached, to be defined in the
Menu Set Min Stock - Page 8
The maximum allowable dispense time has been exceeded, to be defined
in Menu Dispense TO - Page 11
Pulsating beep tone will start.
Only firmware v5.10 and later
An unexpected pulse input arrived while the solenoid valve is closed.
A pulsating beep tone will start.
If this problem persist, please ask the service personnel.
A leaking valve could be the cause.
Only firmware v5.10 and later and Dispense Mode 2
PRESS KEY PRESS
PULSE ALERT
Valve Stuck open
Press any key to
clear error
PRESS KEY PRESS
Dispense Alert
Dispense time
exceeded
Pulse Timeout
001.34
00003.50 L
03:25
13.02.08
!!! WARNING !!!
S T O C K
E M P T Y
000015.00 L
Quit <= => OK
Quit <= => OK
!INPUT - ERROR !
Maximum dispense
quantity exceeded