IOM

General

•  Prior to installation, operation, maintenance or any other type of action carried out on the G75-DFC Filtration 

Controller, read the safety, installation and operation instructions carefully.

•  The G75-DFC Filtration Controller operates as part of larger irrigation systems; therefore, it is essential to comply with 

all the safety instructions and standards relevant to the whole irrigation system.

•  During installation, operation, or maintenance of the controller all conventional, general and local safety instructions 

should be observed in order to avoid danger to the workers, the public or to property in the vicinity.

•  Always use personal safety gear such as gloves, full coverage clothes, helmet, and safety goggles.

•  When installing or servicing the G75-DFC Filtration Controller, use only standard and adequate tools.

•  The G75-DFC Filtration Controller must be used with non-hazardous liquids.

•  The filtration battery controlled by the G75-DFC Filtration Controller enters to backwashing mode automatically 

without warning.

•  No change or modification to the equipment is permitted without a written notification given by Baccara Automation 

& Control.

•  Always observe standard safety instructions and good engineering practices whilst working in the filtration system 

vicinity.

•  Use the G75-DFC Filtration Controller only for its intended use, as designed by the manufacturer, any misuse of the 

controller may lead to undesired damage and may affect your warranty coverage.

Preparation to Installation

•  Shipping and transporting the G75-DFC Filtration Controller must be done in a safe manner and in accordance with 

the relevant standards and regulations.

•  Electrical wiring should be performed by an authorized electrician only, using standardized and approved 

components and tools. Locate the G75-DFC Filtration Controller where direct water splashing on the electrical 

components of the controller is avoided. Prevent electrification; when using an external power, appropriate external 

fuse and wires gauge are required.

•  Install the G75-DFC Filtration Controller where the filtration battery can be clearly seen from its installation point. 

Installation

•  Install the G75-DFC Filtration Controller according to the detailed Installation Instructions provided with it and 

according to the description given in this manual.

•  Leave enough clearance around the G75-DFC Filtration Controller for easy access for safe maintenance.

•  Ensure easy and safe access to the G75-DFC Filtration Controller without climbing on pipes or equipment. Make 

sure that any access equipment is built, installed and used in accordance with the relevant local regulations and 

standards.  

First Startup

•  Carefully observe the First Start-up operation instructions prior to the first operation of the G75-DFC Filtration 

Controller.

•  For smooth operation and performance of the G75-DFC Filtration Controller, make sure to perform the startup and first 

operation procedures exactly as described in this manual.

Operation and Maintenance:

•  Do not operate the G75-DFC Filtration Controller before reading carefully and being familiar with its operation 

instructions.

•  Never operate or use the G75-DFC Filtration Controller for purposes other than its original design and operational 

envelope.

•  When servicing the G75-DFC Filtration Controller, disconnect it and the filters from the power supply.

•  Before returning to regular operation follow the First-time Start-up Operation instructions as detailed in this user 

manual.

SAFETY INSTRUCTIONS

Summary of Contents for G75-DFC

Page 1: ...G75 DFC A U T O M A T I O N C O N T R O L Tackling climate change together Differential Filtration Controller Installation Operation Maintenance IOM...

Page 2: ...part any part of this document or its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this...

Page 3: ...Waterproof Small Wire Connector LV9000 8 DryConn 22 to 12 AWG Wire Connectors 8 Provided by DryConn 8 BATTERY INSTALLATION 9 Before installing the battery 9 Replacing the battery 9 The User Interface...

Page 4: ...replacing a Low Battery icon appears on screen Technical Data Controller Set Supplied with DFC controller suitable for DC only and one analog sensor Mechanical Operating temperature 10 C to 60 C Outdo...

Page 5: ...vant standards and regulations Electrical wiring should be performed by an authorized electrician only using standardized and approved components and tools Locate the G75 DFC Filtration Controller whe...

Page 6: ...ontroller The G 75 DFC Main Components Electric cable Pipe fitting Mounting screws x 2 Pipe fitting Controller D Upper digits UD Lower digits LD DP Pipe fitting Mounting screws x 2 Controller DFC disp...

Page 7: ...e Connects to the black wire of solenoid number 3 filter valve 3 Black wire of the Differential Pressure switch DP Switch Installation Connect the controller s molded cable with the 3 wire connector t...

Page 8: ...ed connection Do not reuse DryConn 22 to 12 AWG Wire Connectors Provide by DryConn 1 Strip 22 18 wires 1 2 12 7mm And 16 12 wires 3 8 9 5mm 2 Align any frayed strands or conductors 3 Pre twisting unne...

Page 9: ...k the cover and secure the four screws The LCD display shows The actual differential pressure DIF The pressure set point SET The flushing cycles counter FC While in flushing a Faucet icon appeases on...

Page 10: ...the controller is paused such as off season or when controlling the filters is not required In the OFF mode the lower line of the controller LD displays OFF In this mode the controller stops reading t...

Page 11: ...samples shortens The maximal interval time between readings is 60 seconds while the minimal interval time between readings is 5 seconds The delay between filters during flushing Off time between valve...

Page 12: ...the above process for filters number 2 and 3 2 Using the and the keys adjust the minutes If A is selected press SET to complete the setting 3 Press SET to continue 4 Using the and the keys adjust the...

Page 13: ...y 1 Incorrect DP settings Low 1 Check if the DP is set too low 1 Set the DP to 0 5 bar 2 Sensor not zeroed 2 Disconnect the upstream and downstream tubes and check that the pressure indicated in the o...