BTEK T403S Indicator User Instructions
27
3.5 Batching application
4.
To stop the batching process, press
STOP
or
F1
. (
F1
toggles the process on
and off.)
3.5.6 Independent setpoints
Independent Setpoint works like the general weighing mode setpoints with the addition
of start/stop controls. You can also do negative weight/discharge using this mode.
1.
Press
SETUP
or press and hold
SELECT
to access the setpoint editor.
2.
Set Out1, Out 2 and Out 3 values.
3.
To start or restart the setpoints, press
START
or
F1
.
4.
To stop the process, press
STOP
or
F1
. (
F1
toggles the process on and off.)
3.5.7 Fill/Discharge
Fill/Discharge mode is typically used for applications that use negative filling to
dispense a smaller amount of product from a large vessel, tank or hopper type scale.
The vessel (tank or hopper) is filled to a set gross weight and then multiple operations
of filling via negative amount of weight into bags or containers can be completed before
the vessel (tank or hopper) requires a recharge or refill.
Fill
Out 1 is assigned as the gross fill amount for the vessel (tank or
hopper) and
START
or
F1
key starts the fill. The fill is based only
on gross weight. If you have Out 1 set to 2000 and the scale
already has 500 lb remaining, the Output 1 will cutoff (and
annunciator
SP1
turns off) when the additional 1500 is added for
a total gross of 2000 lb.
Discharge
Out 2 is assigned as the discharge fill amount (negative weight)
with the
TARE
key used to initiate the discharge cycle. The scale
will tare prior to activating Output 2 (
SP2
annunciator will light). An
operator can perform multiple discharge operations. When the
vessel gross weight is low, perform a refill.
1.
Press
SETUP
or press and hold
SELECT
to access the setpoint editor.
2.
Set Out1 to the gross fill weight in the vessel or container. Set Out 2 to the
weight of the product to be discharged into smaller bags or containers.
3.
To start or restart the large vessel fill process, press
START
or
F1
.
4.
To stop the large vessel filling process, press
STOP
or
F1
.
5.
Press
TARE
to start the bag filling process.
6.
To stop bag filling process, press
STOP
or
TARE
.
Summary of Contents for T403S
Page 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Page 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Page 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Page 73: ......
Page 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...