BTEK T403S Indicator User Instructions
25
3.5 Batching application
3.5 Batching application
This section applies if your indicator has the Batching application active.
3.5.1 SELECT key default function
In the Batching application you can view the gross, net and tare display values by
repeatedly pressing
SELECT
.
3.5.2 Special key functions
The following keys have an extra function in this application:
START
Press
START
to start or resume a batch operation.
STOP
Press
STOP
to pause a batch operation.
Press
STOP
a second time in succesion to abort the batch operation.
F1
F1
acts as a
START
and a
STOP
key on successive presses.
Setpoint or Preact values can be either positive or negative, up to or equal to scale
capacity. See
Entering a negative number on page 11
on how to enter negative values.
The Batch application has added selections for Preact values (1-3) in the Setpoint
menu, shown below:
out1
out2
out3
Setpnt
Preact1
Preact2
Preact3
Press
SETUP
Key in
setpoint
value
Key in
setpoint
value
Key in
setpoint
value
Key in
preact
value
Key in
preact
value
Key in
preact
value
PREACT definition - A preact is the amount of material in free fall.
For example: You would like 1000 lbs of material added to a scale but when the
supply valve closes you always end up with a final weight that is 120 lbs over the
desired amount.
To correct this, set a preact of 120 lbs. This causes the setpoint controlling the
material to stop sooner and allows the material in free fall to be accounted for in the
final weight.
In Discharge or Negative fill applications using manual preact, the preact weight will
typically be entered as a negative value.
Summary of Contents for T403S
Page 1: ...T403S Indicator User Instructions AWT35 501633 Issue AA ...
Page 2: ...BTEK_T403S_u_en_501633 book 2016 B TEK All rights reserved ...
Page 72: ...72 BTEK T403S Indicator User Instructions Supervisor menu ...
Page 73: ......
Page 74: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...