YCJSF Series
14
1.
Gently pull down protective sleeve where piezo lead meets pilot electrode.
2.
Remove piezo lead from pilot electrode.
3.
Undo nut located underneath the pilot electrode on the pilot assembly.
4.
Pull electrode downwards.
5.
Reassemble in reverse order.
Reassemble pilot assembly to burner support bar in reverse order
A
DJUSTMENTS
•
Pilot
1.
Remove front panel as described under GAINING ACCESS TO GAS CONTROLS.
2.
To increase gas pressure to pilot, turn adjustment screw located at the top right hand side of the
flame failure devise anti-clockwise.
3.
To decrease gas pressure to pilot, turn adjustment screw located at the top right hand side of the
flame failure devise clockwise.
4.
REASSEMBLE IN REVERSE ORDER.
Table 4: Troubleshooting
FAULT
Pilot light not igniting
Pilot light not establishing
Pilot established, main burner
not lighting
Telescopic
laundry
arm
constantly running
.
POSSIBLE CAUSE
CHECKS
Blockage of pilot
Adjustment of pressure from flame
failure control
Check pilot injector is not blocked as
described in servicing instructions
–
pilot and flame safeguard
Check gas pressure to pilot as described
under servicing instructions
–
adjustments
Positioning of thermocouple
Check connection of the thermocouple
to the control is not loose.
Faulty thermocouple
Faulty flame failure control valve
Adjust positioning of thermocouple to
ensure
pilot
flame
is
hitting
thermocouple
Contact manufacturer
Position of pilot
Pressure setting of regulator
Is pot in position
Ensure
Adjust pressure to correct pressure
Check that main pot is in position
Worn tap washer