CONTROL CARD TERMINAL FUNCTIONS
Terminal
Function
1
12VDC+ 500mA max
2
DC neutral
3
LED Countdown timer
4
Door closed signal output, closed when door is closed, open when
door is not closed
5
6
Same as 1
7
Safety sensor NC contact with delay (unroll sensor)
8
Open only input, NO
9
Safety sensor instantaneous NC contact (reversing edge)
10
Not used
11
Open/Close input, NO (push button, pull cord, etc.)
12
Pedestrian open input NO
13
Same as 1
14
Photocell input, NC
15
Same as 1
16
Stop button input, NC
17
Encoder signal
18
19
Open over travel switch NO
20
Close only input NO
(Future option)
21
24VAC 700mA source for accessories
22
24VAC neutral
23
Three phase power to motor, change rotation by changing wires on
this connector.
24
25
R
Three phase power to control card
S
T
PE
Three phase PE ground
29
Flashing light output, 230VDC/460VDC
30
DC neutral for 29 and 31
31
Motor brake power, 105VDC
32
Door open signal output, closed when door is open, open when
door is not open