60
To activate this function, configure the settings below:
Configure → Config 2 → External Ref. → Level
Figure 48 - External Reference Voltage Function
13.1.1
AC Couple
AC couple is selected by setting: Configure → Config 1 → Couple → AC. The reference
voltage is proportional to the Instrument voltage.
1 Vdc reference voltage = 30 Vac Instrument
NOTE: Input voltage cannot exceed 0 to 10 V in AC couple mode.
13.1.2
DC Couple
DC couple is selected by setting: Configure → Config 1 → Couple → DC. The reference
voltage is proportional to the source voltage.
±1 Vdc reference voltage = ±42 Vac source
NOTE: Input voltage cannot exceed -10 V to +10 V in DC couple mode.
This function is not supported when Configure → Config 1 → Couple → AC+DC.
13.2
Trigger In
To activate the Trigger function, follow the settings: Configure → Config 2 → External
Ref. → Level.
This instrument has a trigger input on pin 17 of the digital IO interface. Trigger_in is high
at 5 V and low at 0 V. The Instrument will respond to the falling edge of Trigger_in and
Summary of Contents for 9830B Series
Page 1: ...1 9830B Series USER MANUAL Model 9832B 9833B High Power Programmable AC Power Sources ...
Page 10: ...ix 2 Notations TEXT Denotes a softkey TEXT Denotes a front panel key ...
Page 28: ...15 6 Menu Tree ...
Page 86: ...73 THD 11 Harmonic 3 weight 21 3 THD 12 Harmonic 3 weight 24 5 ...
Page 88: ...75 THD 15 Harmonic 5 7 weight 2 45 3 95 THD 16 Harmonic 3 5 7 9 weight 11 4 05 2 1 3 ...
Page 89: ...76 THD 17 Harmonic 3 5 9 weight 7 17 3 42 0 8 THD 18 Harmonic 3 5 9 weight 8 11 3 48 1 ...
Page 95: ...82 THD 29 Harmonic 3 5 7 9 11 13 15 weight 33 3 20 13 8 10 8 8 5 7 2 5 5 ...