Ambient Light Level Adjustment

Control Panel Cover

LED Indicator

OFF   VAC   VAC

TIME

TEST

5

20

30

Min

Min

Min

RANGE

3

2

Mounting Yoke

Fresnel Lens

 OFF  VAC  VAC

4

1

Neutral

White

Hot

Black

Ground

Green

Load

Red

Load

- 01-

-03-

-02-

DESCRIPTION

P

art Number: 97334

       

Voltage .................................................................... 120/277VAC, 60Hz

Incandescent .........................................................................…  800W

Motor  .............................................................................................1/4HP

Time Delay.....................................................................15Sec to 30Mins

SPECIFICATIONS

WAVE-PIR-120/277

 

VACANCY

 

SENSOR 

SWITCH

 

INSTALLATION

 Turn off the circuit breaker before installation.

WARNING:

Do not exceed electrical ratings.

Line(Hot), Red lead to Load wire, Green lead to Ground.

2. Gently position wires in wall box, attach sensor switch to the box.

3. Mount device “TOP”up.

4. Restore power at circuit breaker or fuse, wait

6. Locate the adjustment knobs on the control panel to perform test and

ADJUSTMENT

INSTALLATION INSTRUCTIONS

Light Level......................................................................  30 Lux--Daylight

Indoor use only.

Wiring Diagram:

Figure 2

VAC

Mode

OFF

VAC 

Description

Position

Left

Center

Right

Vacancy Mode: Manual On only, 

automatic Off after set time delay.

React to the push-button

Manually toggles 

Manually toggles 

1. Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to

Coverage Area

Band switch prescription.

5. Remove the small cover plate.  (illustrated as Figure 3. )

7. Replace the small cover plate after testing and adjustment.

8. Attach the wallplate.

Figure 3

On / Off the load.

On / Off the load.

adjustment.(illustrated as Figure 3. )

Default position: 15 Seconds (Test mode)

Adjustable: from 15 Seconds to 30 Minutes (clockwise)

Default position: Center at 65%

Adjustable: 30% (Position 1) to 100% (Position 4)

Note: Turn toward right for greater room space.

      Turn toward left to avoid false alert in smaller room and near 

 the door way or heat source.  

Time Delay knob

Sensor Sensitivity Range Knob

three

 minutes.

Fluorescent/Ballast

/LED

..............  800VA@120VAC /1600VA@277VAC

Ground wire is required.

Manually toggles 

On / Off the load.

       

Operation Temperature....................................................... 32°F--131°F

The coverage range of the sensor switch is specified and illustrated 

the light to turn off  eventhough someone is still in the detection area.

in Figure 1. Large objects and some transparent barriers like glass 

windows will obstruct the sensors' view and prevent detection, causing

Best: 320 sq.ft.

Figure 1

Regular: 800 sq.ft.

Maximum: 1200 sq.ft.

40'

Top View

20'

10'

20'

10'

20'

5'
4'

Circuit is permanently opened
(switched off)

After Initial Run (3 minutes), set the Band Switch to VAC, press and 

hold the Manual ON/OFF Button for 6 seconds until the Load turns on,

release the button within the next 4 seconds, the Load will turn off and

stay off or a maximum 10 seconds. The Load will turn on again (2

seconds) and then Off. It confirms that the present light level becomes

(Push-button)

The passive infrared sensors work by detecting the difference between

heat emitted from the human body in motion and the background space.

If no motion is detected after the set time delay, the load turned off 

automatically. The sensor switch has one relay ( equal to single pole

switch), also includes Ambient Light Level Sensor.

Figure 4

10  Min

Vacancy Mode: Manual On only, 

automatic Off after set time delay.